Tower dryer operations & service, Parts list – Grain Systems PNEG-526 User Manual

Page 47

Advertising
background image

Tower Dryer Operations & Service

PARTS LIST

38

COMMERCIAL TOWER DRYER COMMON SERVICE PARTS (CONTINUED)

Part #

Description

Where Used

GT3-0014

Valve, DeZurich 2"

Used at Beginning of Gas Train - Size Specific

GT3-0198

Valve, DeZurich 3"

Used at Beginning of Gas Train - Size Specific

707-1141-1 O-Ring 2" Dezurich

Replacement Part for 2" DeZurich Valve

707-1140-3 O-Ring 3" Dezurich

Replacement Part for 3" DeZurich Valve

D02-0084

Brass Ball Valve 1/4

Used in Return Line Back to Regulator as Balancing Valve

007-1048-3 Brass Ball Valve 3/4

Used in Gas Train (LP Dryers)

TFC-0093

Valve, 1" NPT Bronze Ball - CGA Approved

Used in Gas Train (LP Dryers)

GT3-0034

Valve, Asco 3/8 NC 120V/60HZ (Pilot)

Gas Train Pilot Solenoid

GT3-0719

Solenoid 1-1/4"

Gas Train Solenoid Between Dual Maxons

TF-1536

Solenoid 1-1/2"

Gas Train Solenoid Between Dual Maxons

TF-1296

Solenoid 3/4 Liquid (LP)

Gas Train Solenoid (LP Oil Only)

707-1694-9 Pressure Gauge 30 oz.

Used in Gas Train After CV Valve

GT3-0131

Pressure Gauge 20 oz.

Used in Gas Train After CV Valve

HH-2984

Pressure Gauge 30 lb.

Used in Gas Train for Incoming Pressure

D02-0103

Pressure Gauge 8-100 lb.

Used in Gas Train (LP Dryers Only)

GT3-0671

Gauge Pressure 2 1/2 Liquid Filled 200 PSI

Used in Gas Train (LP Dryers Only)

007-1829-6 Pressure Gauge 400 lb. (glycerin-filled)

Used in Gas Train (LP Dryers Only)

GT3-0169

Regulator, Gas Equimeter 3" 12112-12

Main Gas Regulator - Size Specific

GT3-0012

Regulator, Gas Equimeter 2.5" 12112-10

Main Gas Regulator - Size Specific

GT3-0471

Regulator, Gas Equimeter 2" 12112-8

Main Gas Regulator - Size Specific

707-1587-5 Regulator Spring Black Rockwell

Standard Spring for Above Regulators

707-1560-2 Regulator Spring Gold Rockwell (cadmium)

Heavier Spring for Above Regulators

GT3-0033

Regulator Fisher 1/2" (Pilot)

Regulates Gas to the Pilot

KD-PES0049 Switch, Low Gas Pressure Honeywell #C6097A1053

Detects Low Gas Pressure in Gas Train

KD-PES0048 Switch, High Gas Pressure Honeywell #C6097B1101

Detects High Gas Pressure in Gas Train

GT3-0624

Valve, Maxon 2" 808

Used in Gas Train (Switches Separate) - Size Specific

GT3-0206

Valve, Maxon 3" 808-CP

Used in Gas Train (Switches Separate) - Size Specific

GT3-0213

Valve, Maxon 4" F 808-CP

Used in Gas Train (Switches Separate) - Size Specific

GT3-1025

Valve, Maxon 6" 808 VLV

Used in Gas Train (Switches Separate) - Size Specific

707-1582-6 Valve, Maxon 2" Motorized 5000 Series

Used in Gas Train (Switches Separate) - Size Specific

GT3-0823

Valve, Maxon 3" Motorized 5000 Series W/VCS-2 Switch

Used in Gas Train - Size Specific

707-1441-5 Valve, Maxon 4" Motorized 5000 Series

Used in Gas Train (Switches Separate) - Size Specific

GT3-1107

Valve, Maxon 6" Motorized 7000 Series

Used in Gas Train (Switches Separate) - Size Specific

Pilot Regulator (All GSI and Zimmerman)

Gas Pressure Switches

Maxon Shut-Off Valves, Switches and Solenoids

Manual 808 Valves

Motorized Valves

Manual Shut-Off Valves

Asco Solenoids

Pressure Gauges

Regulators and Parts

Rockwell

47