TROUBLESHOOTING

33

Message

What to do

AUXILIARY STUCK CLOSED BLOWER 3 STARTER

Check Term 203

AUXILIARY STUCK CLOSED BLOWER 4 STARTER

Check Term. 204

AUX. CONTACT FAILED TO CLOSE TRI-STARTER

Check Term. 200

AUX. CONTACT FAILED TO CLOSE BLOWER 1 STARTER

Check Term. 201

AUX. CONTACT FAILED TO CLOSE BLOWER 2 STARTER

Check Term. 202

AUX. CONTACT FAILED TO CLOSE BLOWER 3 STARTER

Check Term. 203

AUX. CONTACT FAILED TO CLOSE BLOWER 4 STARTER

Check Term. 204

SWITCH OPEN AIR PRESSURE SWITCH 1

Check Term. 205

SWITCH OPEN AIR PRESSURE SWITCH 2

Check Term. 206

SWITCH OPEN AIR PRESSURE SWITCH 3

Check Term. 207

SWITCH OPEN AIR PRESSURE SWITCH 4

Check Term. 306

SWITCH OPEN AIR PRESSURE SWITCH OF

Check Term. 115

COMBUSTION BLOWER

LOST FLAME

Check BCU and Term. 114

SWITCH STUCK CLOSED MAXON VALVE

Check Term. 113

FLAME DETECTED WHILE BURNER IS OFF

Check if pilot or Maxon valves stuck open and check
flame rod, BCU and Term. 114

HI. GAS PRESSURE SWITCH OPEN

Check Term. 111

LOW GAS PRESSURE SWITCH OPEN MAKE

Check gas pressure and Term. 110

SURE MAIN GAS VALVE IS ON
HI. GAS PRESSURE SWITCH OPEN GAS PRESSURE

Check Term. 111

TOO HIGH
LOW GAS PRESSURE SWITCH OPEN GAS PRESSURE

Check Term. 110

TOO LOW

MAXON VALVES NOT TURN ON

Reset and try again

PL. TEMPERATUR RTD CIRCUIT OPEN OR SHORTED

Check the RTD wiring

GRAIN TEMPERATUR RTD CIRCUIT OPEN OR SHORTED

Check the RTD wiring

AUXILIARY STUCK CLOSED OIL PUMP STARTER

Check Term. 307

AUXILIARY STUCK CLOSED COMBUSTION

Check Term. 308

BLOWER STARTER

AUX. CONTACT FAILED TO CLOSE OIL PUMP STARTER

Check Term. 307

AUX. CONTACT FAILED TO CLOSE COMBUSTION

Check Term. 308

BLOWER STARTER

PLUG SWITCH OPEN DRY PATH PLUGGED

Clear dry path and check Term. 309

PLUG SWITCH OPEN HOPPER PLUGGED

Clear hopper and check Term. 310

UNLOAD DRIVE FAULT

Check the drive and Term. 208

OVERLOAD TRIPPED DRY CONVEYOR

Check Term. 305

PLUG SWITCH OPEN WET PATH PLUGGED

Clear wet path and check Term. 311

AUXILIARY STUCK CLOSED DRY CONVEYOR

Check Term. 209

AUXILIARY STUCK CLOSED AUX. DRY CONVEYOR

Check Term. 210

AUXILIARY STUCK CLOSED DRY LEG

Check Term. 211

AUXILIARY STUCK CLOSED TOP DRY CONVEYOR

Check Term. 212

UNLOAD MONITOR PROXIMITY SWITCH OPEN

Check the unload device and Term. 313

AUXILIARY STUCK CLOSED AUX. WET CONVEYOR

Check Term. 215

AUXILIARY STUCK CLOSED WET LEG

Check Term. 214

41