Grain Systems PNEG-526 User Manual

Page 35

Advertising
background image

MAINTENANCE

Tower Dryer Operations & Service

2

PRE-SEASON SERVICE CHECKLIST

_____ Lubricate blower bearings.

_____ Lubricate blower motor bearings, if needed.

_____ Check blower belts and adjust if necessary.

_____ Clean burner ports.

_____ Inspect flame rod and spark ignitor.

_____ Check oil levels in gearboxes.

_____ Inspect divider hopper between heat and cooling section. Clean if necessary.

_____ Inspect Bindicator grain level switches.

_____ Inspect metering system access door cover seals.

_____ Lube metering system access door cover hold down latches.

_____ Lube Modutrol motor linkage.

_____ Check butterfly operation in modulating valve.

_____ Check gas pressure gauges.

_____ Check interior of Maxon shutoff valves for corrosion. Clean if necessary.

_____ Clean control and power panels, tighten loose connections, and check for leaks.

_____ Inspect metering systems. Clean accumulated stalks and old grain.

_____ Start up dryer and check operating controls.

_____ Other: Itemize____________________________________________________

END OF SEASON SHUT-DOWN PROCEDURE

______ Start unload and and empty all grain from dryers.

______ Clean out grain cushion (on plenum roof under fill spout). Clean plenum roof.

______ Clean off grain exchangers.

______ Clean out divider hopper, between heating and cooling section.

______ Clean inside cooling sheets and cooling floor.

______ Remove all grain and trash from unload section of dryer.

______ Open emergency grain discharge doors (and drain doors in Zimmerman dryers).

______ Open drain valve in gas train.

______ Cover burner with a tarp or plastic sheeting.

35