Centripro, Residential water systems – Xylem BMAID R4 User Manual

Page 14

Advertising
background image

PAGE 14

Residential Water Systems

CentriPro

3Ø 4" CENtrIpro motor wIrE Chart

motor lead lengths – 3-phase motors –

Based on Service Factor Amps, 30º C Ambient and 5% Voltage Drop

motor rating

60º C and 75º C Insulation - awG Copper wire Size

Volts

hp

kw

fla

Sfa 14 12 10 8 6 4 2 1/0 2/0 3/0 4/0

.5 .37 3.8 2.9 657 1045 1667 2641 4109

.75 .55 3.8 4.5 423 674 1074 1702 2648

1 .75 4.6 5.5 346 551 879 1392 2166 3454

200

1.5 1.1 6.3 7.2 265 421 672 1064 1655 2638

2 1.5 7.5 8.8 217 344 549 870 1354 2158 3427 5449

3

2.2

10.9

12.0 159 253 403 638 993 1583 2513 3996

5 3.7 18.3 20.2 94 150 239 379 590 940 1493 2374 2995 3781 4764
7.5 5.5 27.0 30.0 64 101 161 255 397 633 1005 1598 2017 2546 3207
.5 .37 2.4 2.9 756 1202 1917 3037 4725 7532

.75 .55 3.3 3.9 562 894 1426 2258 3513 5601 8892

1 .75 4 4.7 466 742 1183 1874 2915 4648 7379

230

1.5 1.1 5.2 6.1 359 571 912 1444 2246 3581 5685 9040

2 1.5 6.5 7.6 288 459 732 1159 1803 2874 4563 7256 9155

3 2.2 9.2 10.1 217 345 551 872 1357 2163 3434 5460 6889 8696 10956
5 3.7 15.7 17.5

318 503 783 1248 1982 3151 3976 5019 6323

7.5 5.5 24 26.4

334 519 827 1314 2089 2635 3327 4192

.5

.37

1.3

1.5

2922

4648

7414

.75

.55

1.7

2.0

2191

3486

5560

8806

1

.75

2.2

2.5

1753

2789

4448

7045

1.5

1.1

2.8

3.2

1370

2179

3475

5504

460

2 1.5 3.3 3.8 1153 1835 2926 4635 7212

3 2.2 4.8 5.3 827 1315 2098 3323 5171

5 3.7 7.6 8.5 516 820 1308 2072 3224 5140

7.5

5.5

12.2

13.5

325

516

824

1305

2030

3236

5138

10 7.5 15.6 17.2 255

405 647 1024 1593 2540 4033

1.5

1.1

2.0

2.4

2283

3631

5792

2

1.5

2.7

3.3

1660

2641

4212

6671

575

3

2.2

3.7

4.1

1336

2126

3390

5370

5 3.7 7.0 7.6 721 1147 1829 2897 4507

7.5

5.5

9.1

10.0

548

871

1390

2202

3426

Advertising