Centripro, Residential water systems, Centripro quick disconnect with pumpsaver insider – Xylem BMAID R4 User Manual
Page 20
Advertising
![background image](/manuals/310180/20/background.png)
PAGE 20
Residential Water Systems
CentriPro
CENtrIpro quICk DISCoNNECt wIth pumpSaVEr INSIDEr
CoNNECtIoNS:
1. Remove the cover from the front of the 3-wire CentriPro control box.
2. Remove the yellow wire from the terminal strip at L2.
3. Remove the black wire connecting L1 and the capacitor completely from the box.
4. Press the PumpSaver
®
onto the L1 and L2 terminals.
5. Reconnect the yellow wire to L2 on the PumpSaver.
6. Connect the blue wire attached to the PumpSaver to the dual-lug terminal (with the black wire) of the
capacitor.
ORANGE
BLUE
BLK
VOLTAGE
RELAY
1
2
5
YEL
YEL
RED
B(MAIN)
Y(COMM)
R(START)
L2
L1
MODEL 111/231
INSIDER
CENTRIPRO CONTROL BOX WITH INSIDER INSTALLED
Advertising