Residential Water Systems

CentriPro

CENtrIpro quICk DISCoNNECt wIth pumpSaVEr INSIDEr

CoNNECtIoNS:

1. Remove the cover from the front of the 3-wire CentriPro control box.

2. Remove the yellow wire from the terminal strip at L2.

3. Remove the black wire connecting L1 and the capacitor completely from the box.

4. Press the PumpSaver

®

onto the L1 and L2 terminals.

5. Reconnect the yellow wire to L2 on the PumpSaver.

6. Connect the blue wire attached to the PumpSaver to the dual-lug terminal (with the black wire) of the

capacitor.

ORANGE

BLUE

BLK

VOLTAGE

RELAY

1

2

5

YEL

YEL

RED

B(MAIN)

Y(COMM)

R(START)

L2

L1

MODEL 111/231

INSIDER

CENTRIPRO CONTROL BOX WITH INSIDER INSTALLED