Centripro, Residential water systems, Jet pump motor data and electrical components – Xylem BMAID R4 User Manual

Page 47

Advertising
background image

PAGE 47

Residential Water Systems

CentriPro

a.o. SmIth motor Data

Gp

where used

a.o. Smith

hp

Volts phase

Service

max. load

watts

Circuit

Number

factor

amps

breaker

J04853

J05, HB705

C48J2DB11C3HF

½ 115/230

1

1.6

10.8/5.4

880

25/15

J05853

JL07N, HSJ07, XSH07, HB

C48K2DB11A4HH ¾ 115/230

1

1.5

14.8/7.4

1280

30/15

J06853

JL10N, HSJ10, SJ10, XSH10, HB

C48L2DB11A4HH

1

115/230

1

1.4

16.2/8.1

1440

30/20

J07858

HSJ15, SJ15, HB, XSH15

C48M2DB11A1HH 1½ 115/230

1

1.3

20.0/10.0

1866

40/20

J08854

HSJ20, HSC20, XSH20

K48N2DB11A2HH

2

115/230

1

1.2

22.6/11.3

2100

25/15

② J09853

XSH30, GT30

C56P2U11A3HH

3

230

1

1.15

17.2

3280

30

② J04853L J5(S), GB

C48A93A06

½ 115/230

1

1.6

10.8/5.4

968

25/15

② J05853L J7(S), GB, GT07, (H)SJ07, HSC07

C48A94A06

¾ 115/230

1

1.5

14.8/7.4

1336

30/15

② J06853L J10(S), GB, GT10, (H)SJ10, HSC10 C48A95A06

1

115/230

1

1.4

16.2/8.1

1592

30/20

② J07858L J15(S), GB, GT15, HSJ15, HSC15

C48M2DC11A1

1½ 115/230

1

1.3

21.4/10.7

1950

40/20

①② J08854L HSJ20, GB, GT20, HSC20

K48A34A06

2

230

1

1.2

12.9

2100

25

SFJ04853 JB05

S48A90A06

½ 115/230

1

1.6

9.4/4.7

900

20/10

SFJ05853 JB07

C48A77A06

¾ 115/230

1

1.5

13.6/6.8

1160

25/15

SFJ06853 JB10

C48A78A06

1 115/230

1

1.4

15.8/7.9

1400

30/20

② SFJ04860 JRS5, JRD5, JB05

C48C04A06

½

115/230

1

1.6

12.6/6.3

990

25/15

② SFJ05860 JRS7, JRD7, JB07

C48C05A06

¾

115/230

1

1.5

14.8/7.4

1200

30/15

② SFJ06860 JRS10, JRD10, JB10

C48C06A06

1

115/230

1

1.4

16.2/8.1

1400

30/20

Effective July, 1998, 230 V only. ② Current production motor

ElECtrICal CompoNENtS

Gp motor

a.o. Smith

motor overload with leads

run Capacitor

Start Capacitor

Switch

model

motor model

old Number New Number t.I. Number

and mfD

mfD rating

J04853

C48J2DB11C3HF

614246 71

MET38ABN

610807 1: 124/148

629002 2

J05853

C48K2DB11A4HH

614246 20

CET63ABN

610807 2: 161/192

629002 2

J06853

C48L2DB11A4HH

614246 9

CET52ABN

610807 2: 161/192

629002 2

J07858

C48M2DB11A1HH

614246 79

CET38ABM

610807 2: 161/192

629002 2

J08854

K48N2DB11A2HH

611307 29

BRT44ABM

614529 4: 25

610807 1: 124/148

629002 2

J09853

_ - 196427-20

611106 22

611106 36

BRB2938

628318 314: 55

610807 11; 36-43

629002 2

J04853L

C48A93A06

614246 98

627121 43

MET39ABN-CL

610807 1:124/148

629002 2

J05853L

C48A94A06

614246 20

627121 38

CET63ABN

610807 2:161/192

629002 2

J06853L

C48A95A06

614246 9

627121 7

CET52ABN

610807 2:161/192

629002 2

J07858L

C48C53A06

611123 21

BRT45ABM

610807 7:189/227

629002 2

J08854L

K48A34A06

616861 10

627119 10

CET31ABN

623450 8: 30

610807 33: 64-77

629002 2

SFJ04853 S48A90A06

621863 1

MEJ38ABN

N/A

3945C91A01

SFJ05853 C48A77A06

621863 4

CET55ABN

610807 2: 161/192

3945C91A01

SFJ06853 C48A78A06

621863 5

CET49ABN

610807 2: 161/192

3945C91A01

SFJ04860 C48C04A06

614246 67

627121 48

MET36ABN

610807 2: 161/192

629002 2

SFJ05860 C48C05A06

614246 20

627121 38

CET63ABN

610807 2: 161/192

629002 2

SFJ06860 C48C06A06

614246 9

627121 7

CET52ABN

610807 2: 161/192

629002 2

These new overload part numbers are for use with the new plastic terminal board with the quick change voltage plug.

Use this suffix if your motor has the old style brown terminal board without quick change voltage plug.

629002 2 replaces 614234 1, 2, and 6.

4

JEt pump motor Data aND ElECtrICal CompoNENtS