Centripro, Residential water systems – Xylem BMAID R4 User Manual
Page 19

PAGE 19
Residential Water Systems
CentriPro
1Ø thrEE-wIrE CoNtrol boX wIrING ChartS
quick Disconnect ½ – 1 hp
wIrING DIaGram
“k” rEpaIr partS for quICk DISCoNNECt StylE CoNtrol boXES
order
Capacitor
Start Capacitor
Start relay
Standard
relay (ohms)
Number
hp
Volts
order
Capacitor
Voltage /
order No.
Circuit breaker
#2-#5
Number
mfd
quantity
CB05411
.5
115
9K450
250 - 300
125 / 1
➀
9K457
30
700 – 1800
➁
9K566
CB05412
.5
230
9K448
59 - 71
250 / 1
➀
9K462
15
CB07412
.75
230
9K449
86 - 103
250 / 1
➁
9K567
20
4500 – 7000
CB10412
1
230
9K447
105 - 126
250 / 1
25
➀
First Design - Up to June 2009 - Relay tab on bottom, capacitor held by bracket and screw. See pictures below. 208 V use 9K461 relay.
➁
Current Design - Starting June 2009 - Relay tab on top and capacitors, all held by one screw. See pictures below. The relays are designed
for operation in a specific orientation, therefore there are two different numbers now. 208 V use 9K568 relay.
First Design
Tab Down ➀
Current Design
Tab Up ➁