If this fault is detect-

ed while the pump is

running, the control-

ler will attempt to

restart three times

before displaying

this fault. To clear the

fault, turn off power

to the controller, wait

1 minute, turn on

power to the control-

ler. If fault persists

contact installer.

The controller will try

to restart the motor

three times before

displaying this fault.

To clear the fault,

turn off power to the

controller, wait 1

minute, turn on

power to the control-

ler. If fault persists

contact installer.

aquaVar Solo

(formerly known as balanced flow)

troublEShootING

fault blINk CoDES

(continued)

rED lIGht CoDES

flashes

Controller Status

Description

3 Blinks

Sensor Fault

(continued)

4 Blinks

Over Current

This fault can be caused by:

• Installing a 1Ø motor - system requires a 3Ø, 200 or 230 V motor.

• Mechanical binding from debris in pump.

• Electrical failure of the motor.

• Incorrect setting of “MOTOR OVERLOAD SETTING (SFA)” switch.

A false “bound pump” error will be displayed if the switch is set too low.

• Pump wire insulation breaking down. Check insulation with megger.

Verify the error by turning power to controller off for 1 minute and then on.

Pump/Motor must be checked if fault persists.

5 Blinks

Short Circuit

This fault can be caused by:

• Electrical failure of the motor.

• Electrical failure of wiring between controller and motor.

Verify the error by turning power to controller off for 1 minute and then on.

If error persists, motor and wiring between controller and motor must be

checked. Turn power off for 1 minute. Remove the three motor wires from the

terminal block. Check wiring and motor for shorting phase to phase and

phase to ground. Refer to motor’s manual for information on resistance

readings.

Pressure (PSI)

Sensor Output vs. Applied Pressure

Transducer Output (V

olts DC)

100 PSI Sensor
200 PSI Sensor

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

5

0

25

50

75

100

125

150

175

200

Advertising