The controller will not

restart if displaying

this fault. To clear the

fault, turn off power

to the controller, wait

1 minute, turn on

power to the control-

ler. If fault persists

contact installer.

The controller will

automatically restart

when the tem-

perature reaches an

acceptable level. If

fault persists contact

installer.

The controller will not

restart if displaying

this fault. To clear the

fault, turn off power

to the controller, wait

1 minute, turn on

power to the control-

ler. If fault persists

contact installer.

The controller will

not restart if display-

ing this fault. To clear

the fault, turn off

power to the control-

ler, wait 1 minute,

turn on power to the

controller. If fault per-

sists contact installer.

WARNING

aquaVar Solo

(formerly known as balanced flow)

troublEShootING

fault blINk CoDES

(continued)

rED lIGht CoDES

flashes

Controller Status

Description

6 Blinks

Ground Fault

This device does not provide personnel protection against shock.

This function is intended for equipment protection only.

This fault can be caused by:

• Electrical failure of the motor

• Electrical failure of wiring between controller and motor.

• Miswiring of motor cable.

Verify the error by turning power to controller off for 1 minute and then on. If

error persists, motor and wiring between controller and motor must be checked.

Turn power off and wait 1 minute. Remove the three motor wires and ground wire

from the terminal block. Check wiring and motor for shorting phase to ground

using a megohmmeter (“megger”). A reading less than 200K Ohms indicates faulty

insulation in the motor cable or motor. Test each to determine fault location.

7 Blinks

Temperature

This fault can be caused by:

• High ambient temperature. The maximum ambient temperature rating is 122ºF

(50ºC).

• Low ambient temperature. The minimum ambient temperature rating is 14ºF

(-10ºC).

Check for a fan failure. The fan will turn on when the temperature inside the

controller reaches 140ºF (60ºC). The fan will turn on for 1 second each time the

controller starts the motor. If the fan never turns on, check fan connections and

replace as needed. Ensure that the external fan intake filter is not blocked or

clogged. It can be removed for cleaning and replacements are available.

8 Blinks

Open Lead

This fault can be caused by:

• Disconnected or broken wire between the controller and motor.

Verify the error by turning power to controller off for 1 minute and then on. If error

persists, motor and wiring between controller and motor must be checked. Turn

power off for 5 minutes. Remove the three motor wires from the terminal block.

Using an ohmmeter, measure the resistance from phase to phase. A disconnected

or broken wire will be indicated by a high resistance reading (20 ohms or higher).

9 Blinks Low Pressure Cut-Off This fault can be caused by:

• Pressure 20 PSI below set point for 30 seconds. May be a broken pipe or tripped

pressure relief valve. If 20 PSI or more pressure drop for 30 seconds is normal for

the system, switch the broken pipe protection off or change system to prevent

the pressure drop.