PAGE 31

Residential Water Systems

CentriPro

To clear the fault, turn

off power to the con-

troller, wait 1 minute,

turn on power to the

controller. If fault per-

sists contact installer.

aquaVar Solo

(formerly known as balanced flow)

troublEShootING

Section 3 Installer Pre-Start Selections is used to indicate system status i.e. running, stopped, or faulted. When
faulted, the status light will be red. The error code is the number of quick flashes followed by a 1 second pause.
The number of flashes can be any number from 2 to 9. The error code will be repeated until cleared. Some errors
will clear themselves with time. Others must be cleared manually by turning the power off for 1 minute. The
following table describes the various errors that can occur.

fault blINk CoDES

No lIGht

flashes

Controller Status

Description

None

Low/No

Check the input voltage to the controller. Measure the voltage between L1 and L2

Input Voltage

using an AC Voltmeter. This voltage should be greater than 190Vac.

None

Controller is in

Check the position of the “RUN/PRG Jumper”. The “RUN/PRG Jumper” is located

Program Mode

in the upper left hand corner of the controller. Refer to Figure 3.

Placing this jumper in “PRG” mode (Program Mode) allows the user to update the

controller’s software through the the controller’s software. When this jumper is in

“RUN” mode (Run Mode), the controller will operate normally.

If the controller is powered while in Program Mode, the status indicator will not

turn on.

To return the controller to Run Mode turn the power off to the controller and wait

5 minutes. Then move the “RUN/PRG Jumper” to “RUN”. Apply power to the

controller. The controller is now in Run Mode.

GrEEN lIGht CoDES

flashes

Controller Status

Description

Constant Standby/Low Voltage Constant Green Light indicates the pump is off. The system is in Standby mode

when there is no flow in the system and the pressure setting has been reached.

The system is in a Low Voltage condition when the line input voltage drops below

190VAC.

Blinking

Pump Running

Flashing Green Light indicates the pump is running.

rED lIGht CoDES

flashes

Controller Status

fault Description

Controller action

This information is to be used by professional installers or qualified personnel only.

Constant

Controller Error

Internal controller fault. Replace controller.