Centripro, Residential water systems – Xylem BMAID R4 User Manual
Page 38
Advertising
![background image](/manuals/310180/38/background.png)
PAGE 38
Residential Water Systems
CentriPro
fuSE ChECkout
1. Set R x 1.
2. Connect leads as shown.
3. Reading: Should register zero.
What It Means –
Zero reading indicates fuse OK. Infinity (∞) reading
indicates bad fuse.
3 phaSE StartEr CoIl ChECkout
open master breaker and disconnect
all leads from starter to avoid
damage to meter or electric shock hazard. Connect
the ohmmeter leads as shown above.
Coil with ohmmeter
1. Set R x 1,000.
2. Connect leads as shown.
3. Reading: Should register some value,
Approximately 200-1000 ohms.
What It Means –
Infinity reading indicates coil is open. Zero reading
indicates coil is shorted. In either case, the coil
should be replaced.
A reading of 200-1000 ohms indicates coil is ok.
WARNING
Advertising