Residential Water Systems

CentriPro

fuSE ChECkout

1. Set R x 1.

2. Connect leads as shown.

3. Reading: Should register zero.

What It Means –

Zero reading indicates fuse OK. Infinity (∞) reading

indicates bad fuse.

3 phaSE StartEr CoIl ChECkout

open master breaker and disconnect

all leads from starter to avoid

damage to meter or electric shock hazard. Connect

the ohmmeter leads as shown above.

Coil with ohmmeter
1. Set R x 1,000.

2. Connect leads as shown.

3. Reading: Should register some value,

Approximately 200-1000 ohms.

What It Means –

Infinity reading indicates coil is open. Zero reading
indicates coil is shorted. In either case, the coil
should be replaced.
A reading of 200-1000 ohms indicates coil is ok.