Centripro, Generation ii centripro motors, Residential water systems – Xylem BMAID R4 User Manual

Page 7: Wire motors

Advertising
background image

PAGE 7

Residential Water Systems

CentriPro

Generation II Centripro motors

2-wIrE motorS

Identified by a - 01 Nameplate Order No. Suffix

As part of Faradyne Motors' continual improvement process we are pleased to introduce the 2 Wire Generation II motors
in April 2011. Our pump model numbers and motor order number will not change. The Motor Nameplate will have a new
Faradyne part number and the Goulds part number on the Motor Nameplate will have a - 01 suffix, example M05422 will be
M05422 - 01, only on the Motor Nameplate not in our catalog or price book.
The self-stick, Mylar motor data stickers we pack with 2 wire motors and complete pumps will be updated with the new
electrical data so that installers will know which motor is installed in the well should service work ever be necessary. Note that
the motor data is only needed to troubleshoot a motor in the well, i.e. resistance and amperage ratings or when installing a
variable speed drive system to set the overloads.

GENEratIoN II – 2-wIrE, 4" SINGlE phaSE ElECtrICal Data, 60 hErtz, 3450 rpm

GENEratIoN II – 2-wIrE, 4" SINGlE phaSE ENGINEErING Data

GENEratIoN II, 2-wIrE motorS, rECommENDED lEaD lENGthS

released for Sale in November/December 2011

Efficiency %

Power Factor %

length

weight

thrust

rating

type

order

No.

hp

kw Volts

f.l.

S.f.

f.l.

S.f.

Inches

mm

lb.

kg.

2-

Wire

(PSC)

M05421

0.5

0.37

115

42%

54%

99%

99%

10.5

267

18

8.2

700 #

M05422

0.5

0.37

230

45%

59%

92%

97%

10.5

267

18

8.2

M07422

0.75 0.55

230

51%

61%

98%

98%

11.9

302

22

9.7

M10422

1.0

0.75

230

50%

59%

98%

98%

12.5

318

24

10.5

M15422

1.5

1.1

230

57%

63%

98%

99%

14.2

361

28

12.4

full load

Service factor locked

rotor

amps

winding

resistance

kVa

Code

type

order

No.

rJ ref. #

hp

kw Volts Sf

amps

watts

amps

watts

2-Wire

(PSC)

M05421

50C201

0.5

0.37

115

1.6

7.9

910

9.8

1120

28

1.4-2.0

H

M05422

50C211

0.5

0.37

230

1.6

4.0

845

4.7

1050

16

6.1-7.2

J

M07422

75C211

0.75 0.55

230

1.5

5.0

1130

6.2

1400

18

5.9-6.9

F

M10422 100C211

1.0

0.75

230

1.4

6.7

1500

8.1

1800

24

4.2-5.2

F

M15422 150C211

1.5

1.1

230

1.3

9.0

2000

10.4

2350

43

1.8-2.4

H

Centripro motor lead lengths - 2-wire motors, 1Ø, 4" motors

Based on Service Factor Amps, 30º C Ambient and 5% Voltage Drop

motor rating

60º C and 75º C Insulation - awG Copper wire Size

Volts

hp

kw

fla

Sfa

14

12

10

8

6

4

2

1/0

2/0

3/0

4/0

115

0.5

0.37

7.9

9.8

112

178

284

449

699

1114

1769

2814

3550

4481

5646

230

0.5

0.37

4.0

4.7

466

742

1183

1874

2915

4648

7379 11733

230

0.75 0.55

5.0

6.2

353

562

897

1420

2210

3523

5594

8895

11222

230

1.0 0.75

6.7

8.1

271

430

686

1087

1692

2697

4281

6808

8590

10843

230

1.5

1.1

9.0

10.4

211

335

535

847

1318

2100

3335

5303

6690

8445

Advertising