Centripro, Residential water systems – Xylem BMAID R4 User Manual
Page 17

PAGE 17
Residential Water Systems
CentriPro
CoNtrol boXES for 6" CENtrIpro (hItaChI) SINGlE phaSE motorS*
Control box
use on
Capacitor ratings (mfD)
Contactor
overload
Enclosure
Shipping
order Number motor No. hp Volts
Start Caps
run Caps
rating
Circuit breaker Dimensions
wt. (lbs.).
CB05MC3R
6M051
5
230
189-227uf / 330V
30 / 440V
30A
30A
12.5" H x
15
CB07MC3R
6M071
7.5 230
243 - 292 / 330V
40 / 440V
50A
50A
11" W x 6.7" D
CB10MC3R
6M101
10 230
(Qty 2)
(2) 25 / 440V
70A
70A
161 - 193 / 330V
17.5" H x
27
CB15MC3R
6M151
15 230
(Qty 2)
(2) 35 / 440V
90A
90A
11" W x 6.7" D
CB15MC3R100 ➀
216 - 260 / 330V
100A
➀
Overload circuit breaker is rated at 100 amps versus 90 amp standard in CB15MC. Use in areas with high ambient temperatures to reduce
nuisance tripping.
* Use these control boxes on only CentriPro (Hitachi) motors. Franklin Electric control boxes will not work and will void the CentriPro warranty.
Do not use these control boxes on Franklin Electric 6" motors as the overloads and capacitors are not the same as used by FE, using these
will void FE's warranty.
5 aND 7.5 hp wIrING DIaGram
10 aND 15 hp wIrING DIaGram