baSIC formulaS aND SymbolS

formulas

GPM = Lb./Hr.

500 x Sp. Gr.

H = 2.31 x psi

Sp. Gr.

H = 1.134 x In. Hg.

Sp. Gr.

H

V

= V

2

= 0.155 V

2

2g

V = GPM x 0.321 = GPM x 0.409

A

(I.D.)

2

BHP = GPM x H x Sp. Gr.

3960 x Eff.

Eff. = GPM x H x Sp. Gr.

3960 x BHP

N

S

= N√GPM

H

3/4

H = V

2

2g

Symbols

GPM

= gallons per minute

Lb.

= pounds

Hr.

= hour

Sp. Gr. = specific gravity
H

= head in feet

psi

= pounds per square inch

In. Hg. = inches of mercury
h

v

= velocity head in feet

V

= velocity in feet per second

g

= 32.16 ft./sec.

2

(acceleration of gravity)

A

= area in square inches (πr

2

) (for a circle or pipe)

ID

= inside diameter in inches

BHP

= brake horsepower

Eff.

= pump efficiency expressed as a decimal

N

S

= specific speed

N

= speed in revolutions per minute

D

= impeller in inches

CENtrIpro or SquarE "D" SwItChES

Grounding

Provisions

#8-32 screws

Range: adjust

for cut-in point

Differential: adjust

for cut-out point

ADJUSTMENT

Line

L1

Load

Load

Line

L2

LINE LOAD LOAD LINE

MOTOR

L1

L2

MAIN SPRING ADJUSTMENT

Turn clockwise to increase both cut-out

and cut-in pressure. (2 PSI/turn)

DIFFERENTIAL

ADJUSTMENT

Turn clockwise to increase

cut-out pressure without

affecting cut-in. (3 PSI/turn)

furNaS pro CoNtrol

adjust in proper sequence:
1. CUT-IN: Turn nut down for higher cut-in pressure, or

up for lower cut-in.

2. CUT-OUT: Turn nut down for higher cut-out pres-

sure, or up for lower cut-out.

Advertising