Residential Water Systems

CentriPro

pump troublEShootING

WARNING

Hazardous voltage

can shock, burn or

cause death.

DISCONNECT AND LOCKOUT ELECTRICAL POWER BEFORE ATTEMPTING ANY SERVICE.
FAILURE TO DO SO CAN CAUSE SHOCK, BURNS OR DEATH.

Symptom

probable Cause

recommended action

pump motor

Not ruNNING

lIttlE or

No lIquID

DElIVErED

by pump

1. Motor thermal protector tripped

a. Incorrect control box
b. Incorrect or faulty electrical connec-

tions

c. Faulty thermal protector
d. Low voltage
e. Ambient temperature of control box/

starter too high

f. Pump bound by foreign matter
g. Inadequate submergence

2. Open circuit breaker or blown fuse

3. Power source inadequate for load

4. Power cable insulation damage
5. Faulty power cable splice

1. Allow motor to cool, thermal

protector will automatically reset

a – e. Have a qualified electrician inspect

and repair, as required

f. Pull pump, clean, adjust set depth as

required

g. Confirm adequate unit submergence in

pumpage

2. Have a qualified electrician inspect and

repair, as required

3. Check supply or generator capacity

4 – 5. Have a qualified electrician inspect and

repair, as required

1. Faulty or incorrectly installed

check valve

2. Pump air bound

3. Lift too high for pump

4. Pump bound by foreign matter

5. Pump not fully submerged

6. Well contains excessive amounts

of air or gases

7. Excessive pump wear
8. Incorrect motor rotation – three phase only.

1. Inspect check valve, repair as required

2. Successively start and stop pump until flow

is delivered

3. Review unit performance, check with dealer

4. Pull pump, clean, adjust set depth as

required

5. Check well recovery, lower pump if possible

6. If successive starts and stops does not

remedy, well contains excessive air or gases

7. Pull pump and repair as required

8. Reverse any two motor electrical leads