Centripro, Residential water systems, Centripro quick disconnect with qd pumptec – Xylem BMAID R4 User Manual

Page 21

Advertising
background image

PAGE 21

Residential Water Systems

CentriPro

CENtrIpro quICk DISCoNNECt wIth qD pumptEC

CoNNECtIoNS:

1. Remove the cover from the front of the 3-wire CentriPro control box.

2. Remove the yellow wire from the terminal strip at L2.

3. Remove the black wire connecting L1 and the capacitor from L1.

4. Press the QD Pumptec onto the L1 and L2 terminals.

5. Reconnect the yellow wire to L2 on the QD Pumptec.

6. Connect the black wire from the capacitor to L1 on the QD Pumptec.

ORANGE

BLACK

BLK

VOLTAGE

RELAY

1

2

5

YEL

YEL

RED

B(MAIN)

Y(COMM)

R(START)

L2

L1

QD

PUMPTEC

L1

L2

CENTRIPRO CONTROL BOX WITH PUMPTEC INSTALLED

Advertising