Residential Water Systems

CentriPro

Generation II – Centripro 3-wire motors – recommended motor lead lengths

Based on Service Factor Amps, 30º C Ambient and 5% Voltage Drop

motor rating

60º C and 75º C Insulation - awG Copper wire Size

hp

Volts

kw

fla

Sfa

14

12

10

8

6

4

2

1/0

2/0

3/0

4/0

0.5

115

0.37

8.8

10.9

101

160

255

404

629

1002

1591

2530

3192

4029

5076

0.5

230

0.37

5.3

6.1

359

571

912

1444

2246

3581

5685

9040

-

-

-

0.75

0.55

6.6

7.8

281

447

713

1129

1757

2800

4446

7070

8920

-

-

1.0

0.75

8.1

9.4

233

371

592

937

1458

2324

3689

5867

7402

-

-

1.5

1.1

9.1

10.9

201

320

510

808

1257

2004

3182

5059

6383

-

-

2.0

1.5

9.9

12.2

180

286

456

722

1123

1790

2843

4520

5703

-

-

3.0

2.2

14.3

16.5

133

211

337

534

830

1324

2102

3342

4217

5323

-

5.0

3.7

24

27

-

-

206

326

507

809

1284

2042

2577

3253

-

3-wIrE, SINGlE phaSE 4" motorS - ElECtrICal Data, 60 hErtz, 3450 rpm

Generation II

– released for sale in february/march 2012

full load

Service factor locked

rotor

amps

winding

resistance

required

Control box

1

type

order

No.

rJ ref.

#

hp kw Volts Sf

amps watts amps watts

main

(b-y)

Start

(r-y)

3-

Wire

with

Q.D.

Cap.

Start

Box

M05411 50C301 0.5 0.37 115

1.6

Y – 8.8

B – 8.8

R – 0

675

Y – 10.9

B – 10.9

R – 0

980

44

1.0 -

1.4

2.5 -

3.1

CB05411

M05412 50C311 0.5 0.37

230

1.6

Y – 5.3

B – 5.3

R – 0

740

Y – 6.1

B – 6.1

R – 0

1050

21

5.1 -

6.1

12.4 -

13.7

CB05412

M07412 75C311 0.75 0.55

1.5

Y – 6.6

B – 6.6

R – 0

970

Y – 7.8

B – 7.8

R – 0

1350

32

2.6 -

3.3

10.4 -

11.7

CB07412

M10412 100C311 1.0 0.75

1.4

Y – 8.1

B – 8.1

R – 0

1215

Y – 9.4

B – 9.4

R – 0

1620

41

2.0 -

2.6

9.3 -
10.4

CB10412

3-

Wire

with

CSCR

(CR)

or

Mag-

netic

Con-

tactor

(MC)

Con-

trol

Box

M05412 50C311 0.5 0.37

1.6

Y – 4.2

B – 4.1

R – 1.8

715

Y – 4.8

B – 4.3

R – 1.8

960

21

5.1 -

6.1

12.4 -

13.7

CB05412CR

M07412 75C311 0.75 0.55

1.5

Y – 4.8

B – 4.4

R – 2.5

940

Y – 6.0

B – 4.9

R – 2.3

1270

32

2.6 -

3.3

10.4 -

11.7

CB07412CR

M10412 100C311 1.0 0.75

1.4

Y – 6.1

B – 5.2

R – 2.7

1165

Y – 7.3

B – 5.8

R – 2.6

1540

41

2.0 -

2.6

9.3 -
10.4

CB10412CR

M15412 150C311 1.5

1.1

1.3

Y – 9.1

B – 8.2

R – 1.2

1660

Y – 10.9

B – 9.4

R – 1.1

2130

49

2.1 -

2.5

10.0 -

10.8

CB15412CR or

CB15412MC

M20412 200C311

2

1.5

1.25

Y – 9.9

B – 9.1

R – 2.6

2170

Y – 12.2

B – 11.7

R – 2.6

2660

49

1.6 -

2.2

4.8 -

5.9

2

CB20412CR or

CB20412MC

M30412 300C311

3

2.2

1.15

Y – 14.3

B – 12.0

R – 5.7

3170

Y – 16.5

B – 13.9

R – 5.6

3620

76

1.0 -

1.4

2.0 -

2.5

CB30412CR or

CB30412MC

M50412 500C311

5

3.7

1.15

Y – 24.0

B – 19.1

R – 10.2

5300

Y – 27.0

B – 22.0

R – 10.0

6030

101

.6 - .8

1.3 -

1.7

CB50412CR or

CB50412MC

¹ A CSCR control box with a CR suffix can be replaced by a Magnetic Contactor model ending in MC.

2

Prior to November 2012, the Winding Resistance was 10.8 – 12.0.

GENEratIoN II – 3-wIrE, 4" SINGlE phaSE rECommENDED wIrE lENGthS