Installation procedures, Step 2 – mounting the aquavar model 56 controller, Continued – Xylem IM098 AQUAVAR Model 56 Controller User Manual

Page 11

Advertising
background image

Gasket

4 screw
M5x50

Center bit

4 mounting
clamps

Connection
motor
conduit box

Thermistor

Transducer

Installation Procedures

6

Step 2 – Mounting the AQUAVAR Model 56 Controller

(AV 1.15, AV 2.2 style)

continued

155

70

Cable entries

Closing cap

Type

Weight (kg)

AV 1.15

4.70

AV 1.2

4.70

2) Mounting:

• Remove the 3 screws from the AQUAVAR

cover.

• Place the center bit in the AQUAVAR heat

sink.

• Place the AQUAVAR on the motor.
• Hang the 4 clamps by the motor fan cover

and mount with the 4 screws to the
AQUAVAR.

• Replace the AQUAVAR cover with the

3 screws.

Don't forget the gaskets for the 3 screws.
Ensure that there is no water on the unit
before you open the cover.