Pressure Transducer
The sensor of this transducer is a piezoresistive silicon pressure sensor, mounted on a tape (TAP)
floating freely in an oil chamber. The pressure is transferred to the sensor by a separating nickel
diaphragm in the oil chamber.
Specifications
Range (FS):
150 psi (other range upon request)
Over-pressure-Pmax:
300 psi
Class of protection:
IP 67
Type
Sealed gauge:
Signal Over Range:
0,5 - 4,5 V DC (ratiometric)
Supply:
5 VDC +/- 025 VDC
Supply:
+ VCC => red = supply voltage
+ Out => white analogue output signal
GND => black ground
Operating Temperature:
-20 - +80°C
Storage Temperature:
-40 - +100°C
Material:
Body Steel and Brass
Diaphragm:
Nickel
Pressure Transducer
Plug
1
⁄
4
" NPT THREAD
+ out (0.5 – 4.5 V)
GND
+FCC (5V)
39