Connect the cable, 5 commissioning, startup, operation, and shutdown, 1 prime the pump – Xylem e-HM User Manual

Page 11: 2 check the rotation direction (three-phase motor), 3 start the pump, 6 maintenance

Advertising
background image

trol panel are isolated from the pow-

er supply and cannot be energized.

Grounding (earthing)

Electrical Hazard:

• Always connect the external protec-

tion conductor to ground (earth) ter-

minal before making other electrical

connections.

Connect the cable

1. Connect and fasten the power cables accord-

ing to the wiring diagram under the terminal

box cover.

a) Connect the ground (earth) lead.

Make sure that the ground (earth) lead is lon-

ger than the phase leads.

b) Connect the phase leads.

NOTICE:
Tighten the cable glands carefully to ensure

the protection against the cable slipping and

humidity entering the terminal box.

2. If the motor is not equipped with automatic re-

set thermal protection, then adjust the over-

load protection according to the nominal cur-

rent value of electric pump (data plate).

5 Commissioning, Startup,
Operation, and Shutdown

Precautions

WARNING:
Make sure that the drained liquid does

not cause damage or injuries.

NOTICE:

• Never operate the pump below the minimum

rated flow.

• Never operate the pump with the delivery ON-

OFF valve closed for longer than a few seconds.

• Do not expose an idle pump to freezing condi-

tions. Drain all liquid that is inside the pump.

Failure to do so can cause liquid to freeze and

damage the pump.

• The sum of the pressure on the suction side

(water mains, gravity tank) and the maximum

pressure that is delivered by the pump must not

exceed the maximum working pressure that is

allowed (nominal pressure PN) for the pump.

• Do not use the pump if cavitation occurs. Cavi-

tation can damage the internal components.

Noise level
The sound pressure level of the units is lower than

70 LpA.

5.1 Prime the pump

For an illustration that shows the pump parts, see

Figure 6

.

1. Fill plug

2. Drain plug

3. Funnel

Installations with liquid level above the pump
(suction head)

1. Close the on-off valve located downstream

from the pump.

2. Remove the fill plug and open the on-off valve

upstream until the water flows out of the hole.

3. Close the fill plug.

Installations with liquid level below the pump
(suction lift)

1. Open the on-off valve that is located upstream

from the pump and close the on-off valve

downstream.

2. Remove the fill plug and use a funnel to fill the

pump until water flows out of the hole.

3. Replace the fill plug.

5.2 Check the rotation direction (three-
phase motor)

Follow this procedure before start-up.

1. Locate the arrows on the pump or the motor

fan cover to determine the correct rotation di-

rection.

2. Start the motor.
3. Quickly check the direction of rotation through

the motor fan cover.

4. Stop the motor.
5. If the rotation direction is incorrect, then do as

follows:

a) Disconnect the power supply.

b) In the terminal board of the motor or in the

electric control panel, exchange the position

of two of the three wires of the supply cable.

c) Check the direction of rotation again.

5.3 Start the pump

1. Start the motor.
2. Gradually open the on-off valve on the dis-

charge side of the pump.
At the expected operating conditions, the

pump must run smoothly and quietly. If not, re-

fer to

Troubleshooting

.

3. If the pump does not start in correctly in

30 seconds, then do the following:

a) Switch off the pump.

b) Reprime the pump.

c) Start the pump again.

4. Switch off and on the pump (for about 30 sec-

onds of continuos running) and make sure that

all the trapped air is bled out by repeating this

2–3 times.

NOTICE:
Make sure that the pump has bled away all the

trapped air. Failure to do so can harm the product.

6 Maintenance

Precautions

en - Translation of the original instructions