Xylem Aquontroller User Manual

Page 52

Advertising
background image

en

en

en

en

52

50

t1 PowerSupplied

MMA
MMW

R

1=
1,85h

0

65535

Varie

Displays the total time on supply, expressed in proprietary units.
1 unit = 1.82 hours (400=1 month, 4800=1 year).

51

t0 in Operation

MMA
MMW

R

0.1x
sec

0

65535

Varie

Displays the total operating time, expressed in proprietary units. 1 unit = 0.1 seconds.
After 65535 = 1,82 hours the par 50 is increased by one unit.

52

t1 in Operation

MMA
MMW

R

1=
1,85h

0

65535

Varie

Displays the total operating time, expressed in proprietary units.
1 unit = 1.82 hours (400=1 month, 4800=1 year).

53

Time Delta bar

MMA

RW

sec

0

80

5,0

Delay during which the inverter attempts to stop. Enabled when pressure and
frequency are constant. Connected with parameter 47.

54

Pmax NoWater

MMA

R

Watt

30

5000

599

Maximum power input of pump with no flow. Parameter used to monitor pump
operation, particularly in the dry-running condition.

55

Remote On Enable

MMA

RW

N

0000

0001

0000

If ON, the driver is enabled to operate via a digital external command (contact open =
inverter standby).

58

Time StopPump

MMA
MMW

RW

0.1x
sec

29000=
48min

Set the time, over 24 hours, the pump must be stopped. Default 45 minutes. If this
time is exceeded the display shows "leaks". In the sixth event (fixed number), the drive
stops completely. Must be turned off, check the status of the system by eliminating the
losses, if any. Parameter needed to diagnose problems of the drive to stop.

59

C.Time StopPump

MMA
MMW

R

sec

0

1440

Varie

Within 24 hours, shows the time in which the engine is stopped. Parameter used to
diagnose the presence of leakage.

60

Leakages

MMA
MMW

R

N

0

100

Varie

Counts the number of times the continuous pump operating time exceeds the hold
time t0 Pump Off (par 58). By default, so as not to increase the number of leaks, the
pump must not operate for at least 54 mins within a 24 hour timescale. If the "leaks"
message appears, check whether there are leaks in the system or check times and
settings.

62

I DC-Offset

MMA
MMW

RW

N

0

1023

90

Zero-setting the power reading made by the driver (par 46). Parameter only available in
multiple pump systems.

63

TimePmaxNoWater

MMA
MMW

R

sec

Varie

Displays the time elapsed (timer) in the alarm and no water or insufficient pressure.
In the absence of flow with a frequency greater than 45Hz, the timer is incremented.
MMA Version: power less than the value set in par (54) and higher frequency at 45Hz.
MMW Version: Flow valve closed and a frequency above 45Hz.

64* MinTresholdPar %

MMA
MMW

RW

%
Watt

0

90

50

This parameter must be set to default value “50”

65

Tot. ShortC Done

MMA
MMW

RW

N

0

1000

40

Phase-phase or phase-ground short circuit counter. Default value 40.

66

SerialNumber 1

MMA
MMW

….

Serial number

67

SerialNumber 2

MMA
MMW

Not in use

72

Nominal Value

MMA

RW

bar

0.3

MMW07: 7.5

2.5

Set the required system pressure (set point).