Setpoint, Range low – YSI 5200 User Manual

Page 41

Advertising
background image

YSI Incorporated

39

5200 Recirculating System Monitor

S e t P o i n t M e n u

E n t e r t o S e l e c t

Press the Enter [



] key.

E n t e r t o S e l e c t

S e t P o i n t

Set Point Menu selections for Temperature are SetPoint, Range Low, Range High, Alarm Low and Alarm
High.

SetPoint

The Temperature Set Point defines the optimum Temperature that you wish the YSI 5200 to maintain in
the aquatic environment. This determines the control range for heating and chilling devices. See Section
5.3.1 Entering Setpoint and Range Values for an overview of control functions.

From the Set Point menu (with the SetPoint option displayed), press the Enter [



] key.

S e t P o i n t
0 7 7 . 0 ° F

Using the [e], [f] and Enter [



] keys, enter the Temp Set Point value.

NOTE: The previous value entered will be displayed.

S e t P o i n t
0 6 9 . 0 ° F

Press the Enter [



] key. The display returns to the Set Point Menu.

E n t e r t o S e l e c t

S e t P o i n t

Press the [f] key for the next Set Point selection, Range Low.

Range Low

From the Set Point menu (with the Range Low option displayed), press the Enter [



] key.

R a n g e L o w
0 6 8 . 9 ° F

Using the [e], [f] and Enter [



] keys, enter the Temperature Range Low value.

NOTE: The Range Low value must be lower than the Set Point.

R a n g e L o w
0 6 5 . 0 ° F

Press the Enter [



] key. The display returns to the Set Point Menu.

E n t e r t o S e l e c t

R a n g e L o w

Press the [f] key for the next Set Point selection, Range High.