10 understanding the status bar – YSI 600DW-B Sonde User Manual

Page 126

Advertising
background image

650 MDS

Section 3

Section 3.11 of this manual. If symptoms persist after these actions, consult YSI Customer Service for
advice.



3.2.10 UNDERSTANDING THE STATUS BAR


The diagram below shows the various components of the Status Bar of your 650. Each item identified in the
drawing is explained in detail below.













Main Display

Status Bar

Date and Time

GPS Reading

Barometer Reading

Battery Capacity Status

Menu Indicator

2.10.1 Date and Time. This is the date and time for the clock in the 650, set by the user from the System
setup
menu as described above. The date and time entries are updated in real-time in the Status Bar.

2.10.2 GPS Reading. This value will be present only if a user-supplied GPS unit with NMEA 0183 format
is connected to the 650 by the optional YSI 6115 cable. The setup of a GPS interface is described in more
detail in Section 3.8 below. Once properly connected to a GPS instrument, the values displayed in the
Status Bar are updated in real-time as the system is moved from location to location.

2.10.3 Barometer Reading. This value is the current local barometer reading in units selected by the user
in the System setup menu. The value is can be used simply as a meteorological parameter or can be used
in calibration of sonde dissolved oxygen sensors. The barometer reading is NOT corrected to sea level and
is updated in real-time.

2.10.4 Battery Capacity Status. The graphic indicator shows the portion of the battery capacity that is
remaining, either for the 4-C cell configuration or for the optional rechargeable battery pack. If a 6117
rechargeable battery pack is in place, a “NiMH” label will appear as part of the indicator. During charging
of the battery pack, the black portion of the icon will pulse horizontally until charging is complete. In
addition, the entire battery indicator will flash when your batteries are almost exhausted and require
replacement (C-cells) or recharge (optional rechargeable battery pack).

2.10.5 Menu Indicator. This icon is located in the lower right portion of the Status Bar and provides a
guide as to whether the menu on the display of the 650 originates in the sonde or the 650 itself. The icon
shown in the figure above represents a 650 menu; if the menu on the display had originated in the sonde,
the Status bar would display a sonde-like icon as shown below.

YSI, Incorporated Drinking Water Monitoring Systems Operations Manual

3-17

Advertising
This manual is related to the following products: