Using edids, Edid minder – Extron Electronics MLS 608 D Series User Guide User Manual

Page 28

Advertising
background image

Use this volume adjustment knob to set or adjust the program output volume
(attenuation, from -100 dB to 0 dB) as desired. The LEDs indicate the overall
percentage level for Group Master 1; the volume level being all off (0%) at -100 dB
through to all on (100%) at -4 to 0 dB. Any level changes made do not affect the mic
audio.

Rotate the knob clockwise to increase volume,
counter-clockwise to decrease volume. The
corresponding LEDS light as the knob is rotated.
See the table at right for LED/dB values.

Volume control of Group 1 individual program
outputs (programs 1, 3, or 4) can be made
through DSP Configurator software. Group 1
can be reconfigured through DSP Configurator
software.

f

Mic volume adjustment knob This knob

is assigned to Group Master 2, which controls
the mic inputs at the second gain block, pre-mic
mixer-gain programs (

see figure 12

). By default it controls both microphones, and

level changes do not affect the program audio.
Use this knob to set or adjust the two MIC volumes as desired from -100 dB to 0 dB.
The LEDs indicate the volume level. See the table at above right for LED/dB values.

Rotate the knob clockwise to increase volume, counter-clockwise to decrease volume.
The corresponding LEDS light as the knob is rotated.

Volume control of Group 2 individual mic levels (mic pre-mixer gains 1 and 2) can be
made through DSP Configurator software.

Group 2 can be reconfigured through DSP Configurator software.

NOTE:

The program and mic volume settings and adjustments can also be made
using Extron DSP Configurator program or by Simple Instruction Set (SIS)
commands. See the “

Using the DSP Configurator Software

”section

and the “

SIS Programming and Control

” section for details.

Using EDIDs

EDID Minder

This pre-installed feature ensures that all sources power up properly and reliably
output content for display. EDIDs (resolution and refresh rates) for digital inputs can be
automatically assigned when connecting a display with a common resolution and refresh
rate. For both analog and digital, the user can assign a different EDID from an EDID table.

A different EDID (as given in the table on the next page), can be manually assigned using
SIS commands or via DSP Configurator.

For the MLS 608 D units, the default settings are 1024x768 at 60 Hz for analog inputs,
and 720p at 60 Hz, 2-channel PCM audio for digital inputs.

NOTES:

To work with the EDID Minder, update the EDID table, and import or export

EDID data, the MLS 608 D must be connected in Live mode.

VOLUME

LED equivalent

dB value

-4 to 0

-9 to -5

-14 to -10

-19 to -15

-29 to -20

-49 to -30

- 69 to -50

-99.9 to -70

-100 (all LEDs

off)

MLS 608 D Series • Operation