Extron Electronics MLS 608 D Series User Guide User Manual

Page 82

Advertising
background image

Command

ASCII Command

(host to switcher)

Response

(switcher to host)

Additional

Description

Reset (Zap)/Erase Commands

Reset all video and
audio settings to
factory default

E

ZXXX}

Zpx]

Resets all video and audio
settings.

Reset all settings to
factory default

E

ZQQQ}

Zpq]

Resets all video and
audio settings, protected,
configuration, verbose mode,
and control port settings.

NOTE:

This command is the same as reset mode 5.

See the Mode 5 details

in the "Operations" section.

Delete all presets and
names

E

ZG}

Zpg]

Removes all presets and preset
names.

Delete individual
preset

EX1@

ZG}

ZpgX1@]

Removes a selected preset.

Bidirectional Serial Port Commands

Configure
parameters

24

E

1*X4$,X4%,X4^,X4& CP}

Cpn01X4$,X4%,X4^,X4&]

Set baud rate X4$, parity
X4%, data bits X4^, and
stop bits X4&.

View parameters

E

1CP}

X4$

,X4%,X4^,X4&]

View baud rate X4$,
parity X4%, data bits X4^,
and stop bits X4&.

Verbose settings

Set verbose mode

EX4*

CV}

VrbX4*]

Set verbose mode
parameters.

View parameters

E

CV}

X4*]

View verbose mode
parameters.

Unit name

Set unit name

EX5@

CN}

Ipn•X5@]

Set unit name.

Set unit name to
default

E•

CN}

Ipn•X5#]

Set unit name to default

View unit name

E

CN}

X5@]

View unit name

NOTE:

X1@ = Preset number: 1-8

X4$ = Baud rate: 300, 600, 1200, 1800, 2400, 3600, 4800, 7200, 9600, 28800, 38400 (default), 57600, 115200
X4% = Parity, Odd, Even, None (default), Mark, Space (only use first letter, for example N = None)

X4^ = Data bits: 7, 8 (default = 8)

X4& = Stop bits: 1, 2 (default = 1)

X4* = Verbose mode: 0 = no verbose mode and non-tagged responses for queries, 1 = verbose mode and non-tagged

responses for queries (default), 2 = no verbose and tagged responses for queries, 3 = verbose mode and tagged

responses for queries

X5@ = Alpha numeric up to 24 characters. No special characters except hyphen (-). No lower or upper case distinction,

no blanks or spaces. First character must be alpha, last cannot be hyphen.

X5# = Alpha numeric name. Combination of unit name and last three pairs of unique alpha-numeric characters,

(for example MLS-608-D-MA-06-DE-2E).

MLS 608 D Series • SIS Programming and Control

76

Advertising