Command

ASCII Command

(host to switcher)

Response

(switcher to host)

Additional

Description

Power Save Mode

Turn power save off

E

0PSAV}

PsavX3$]

Turn power save on

E

1PSAV}

PsavX3$]

View power save

E

PSAV}

X3$]

View power save status.

Front panel security lockout (Executive Mode)

Enable Executive mode 1

1X

Exe1]

Lock out front panel
buttons and knobs.

Enable Executive mode 2

2X

Exe2]

Lock out front panel
buttons only.

Disable Executive mode

0X

Exe0]

Unlock all front panel
controls.

View Executive mode
status

X

0 ] (or) 1 ]
(or) 2 ]

View the current status:
0 = off [default]; 1 =
on, lock all buttons and
knobs; 2 = on, lock input
buttons only.

Information Requests

View firmware
version

Q or 1Q

x.xx]

View the firmware
version.

View part number

N

X3&]

View the part number
X3&.

View AV input

I

VidX!•AudX!]

View current AV input.

View model name

1I

X3*]

View model name X3*.

View video signal
presence

LS

X3(

*X3(*X3(*X3(*X3(*X3(*

X3(

*X3(]

Shows signal presence
for all inputs, 1-8.

View +1.5V FPGA
voltage

15S

+X4)]

View internal temp
in °C

20S

+X4!]

View audio mute
to DSP

40S

X4@]

NOTE:

X! = Input selection: 0-8, 0 = no connection

X3$ = Power save mode: 0 = off (default), 1 = on
X3& = Device part number: 60-1050-01 = MLS 608 D, 60-1050-02 = MLS 608 D MA, 60-1050-03 = MLS 608 D SA
X3* = MLS 608 D, or MLS 608 D MA, or MLS 608 D SA

X3( = Video signal status: 0 = video /TMDS not detected, 1 = video /TMDS detected, - = unknown

X4) = Voltage in volts (V)
X4! = Temperature in degrees C, response is three digits with leading zeros (for example 031 = 31°C)

X4@ = Audio mute to DSP: 0 = audio unmuted, 1 = audio muted