Extron Electronics MLS 608 D Series User Guide User Manual

Page 76

Advertising
background image

Command

ASCII Command

(host to switcher)

Response

(switcher to host)

Additional

Description

Set Group Master Value

Set value (dB)

E

DX^*X*GRPM}

GrpmDX^*X*]

Set the value X* for
group number X^.

NOTE:

Reserved groups are: 1 = program volume, 2 = mic volume, 3 = output bass, 4 = output treble, 5 = output volume mute.

Audio mute or
unmute

E

DX^*X%GRPM}

GrpmDX^*X%]

Mute or unmute X% for
group number X^.

Increment value

E

DX^*X&+GRPM}

GrpmDX^*X&]

Increase the value by X&
for group number X^.

Decrement value

E

DX^*X&-GRPM}

GrpmDX^*X&]

Decrease the value by X&
for group number X^.

View master value

E

DX^GRPM}

X*]

View group master value
X*.

Program Volume (Group Master 1)

Set value (dB)

E

D1*X*GRPM}

GrpmD

0

1*X*]

Set the value X* for
group master 1.

Example: ED1*

0

GRPM}

GrpmD

0

1*+

00000

]

Sets the value to 0 dB.

Example: ED1*-1

00

GRPM}

GrpmD

0

1*-

00100

]

Sets the value to -10 dB.

Example: ED1*-1

000

GRPM}

GrpmD

0

1*-

01000

]

Sets the value to -100
dB.

Increment value

E

D1*X&+GRPM}

GrpmD

0

1*X*]

Increase the value X*
by X&.

Decrement value

E

D1*X&-GRPM}

GrpmD

0

1*X*]

Decrease the value X*
by X&.

View master value

E

D1GRPM}

X*]

View current program
volume master value X*.

Mic Volume (Group Master 2)

Set value (dB)

E

D2*X*GRPM}

GrpmD

0

2*X*]

Set the value X* for
group master 2.

Example: ED2*

0

GRPM}

GrpmD

0

2*+

00000

]

Sets the value to 0 dB.

Example: ED2*-1

00

GRPM}

GrpmD

0

2*-

00100

]

Sets the value to -10 dB.

Example: ED2*-1

000

GRPM}

GrpmD

0

2*-

01000

]

Sets the value to -100
dB.

Increment value

E

D2*X&+GRPM}

GrpmD

0

2*X*]

Increase the value X*
by X&.

Decrement value

E

D2*X&-GRPM}

GrpmD

0

2*X*]

Decrease the value X*
by X& .

View master value

E

D2GRPM}

X*]

View master mic volume
value X*.

NOTE:

X% = Audio mute: 0 = no mute, 1 = mute

X^ = Group master number: 1 through 32, groups 1 through 5 are reserved groups, see note above.

X& = Increment and decrement dB values: in 0.1 dB steps (multiply dB by 10, for example 10 = 1.0 dB).

X* = Master volume value: 0 to -100 dB, in 0.1 dB steps, For example 0 = 0 dB, -1 = -0.1 dB,

-10 = -1.0 dB, -100 = -10 dB, -1000 = -100 dB.

See master volume table on page 64 for details

.

X( = Group member OID number