5 model 705 menu: step-by-step procedure – Orion Instruments Eclipse 705 User Manual

Page 21

Advertising
background image

21

57-600 Eclipse

®

Guided Wave Radar Transmitter

2.6.5 Model 705 Menu: Step-By-Step Procedure

The following tables provide a complete explanation of
the software menus displayed by the ECLIPSE transmitter.
Use these tables as a step-by-step guide to configure the
transmitter based on a desired measurement type of:

• Level Only, Section 2.6.5.1

• Level and Volume, Section 2.6.5.2

• Interface Level, Section 2.6.5.3

• Interface Level and Volume, Section 2.6.5.4

The tables are separated to display the parameters based
on the measurement type. The second column presents
the menus shown on the transmitter display. The displays
are in the order they would appear if the arrow keys were
used to scroll through the menu. The numbers in the first
column are not shown on the display. They are only pro-
vided as a reference.

The third column provides the actions to take when con-
figuring the transmitter. Additional information or an
explanation of an action is given in the fourth column.
(Shaded sections are factory menu items).

2.6.5.1 Measurement Type: Level Only (Loop Control = Level)

Display

Action

Comment

1

*Status*
*Level *

*% Out *
* Loop *

Transmitter Display

LoopCtrl = Level.
Transmitter default display showing Status, Level, % Output, and
Loop values cycles every 5 seconds

2

Level
xxx.x

Transmitter Display

Transmitter displays Level Value in selected units

3

% Output

xx.x%

Transmitter Display

Transmitter displays % Output measurement derived from 20 mA
span

4

Loop

xx.xx mA

Transmitter Display

Transmitter displays Loop value (mA)

5

PrbModel
(select)

Select the type of probe
used

(Example: 7xR-x)

Select from 7xA-x, 7xB-x, 7xD-x, 7xE-x, 7xF-x, 7xF-E, 7xF-F,
7xF-4, 7xG-x, 7xF-P, 7xG, 7xJ-x, 7xK-x
, 7xL, 7xM, 7xN, 7xP-x,
7xR-x, 7xS-x, 7xT-x, 7x1-x, 7x2-x, 7x5-x, 7x7-x as shown on
the probe nameplate

6

PrbMount
(select)

Select the type of probe
mounting

Select from NPT, BSP, or Flange

7

MeasType
(select)

Select type of measurement

Select Lvl Only

8

LvlUnits
(select)

Select level units

Select from cm, inches, feet or meters

9

Probe Ln

xxx.x

Enter the exact length of
probe

Probe length is printed on the nameplate and order information
and is the last three digits of the probe model number

10

Lvl Ofst

xxx.x

Enter the desired reading
when probe is dry

Level Offset is the distance from the probe tip to the desired 0
level point (-90 to 300"). Refer to Section 2.6.6

11

Dielctrc
(select)

Select range bounding the
dielectric constant of the
media

Select from 1.4–1.7; 1.7–3; 3–10; 10–100

Advertising