5 probe specifications, Dual-element probes, Single rod probes – Orion Instruments Eclipse 705 User Manual

Page 55

Advertising
background image

Dual-element Probes

55

57-600 Eclipse

®

Guided Wave Radar Transmitter

Single Rod Probes

Distance to Probe

Acceptable Objects

<6"

Continuous, smooth, parallel conductive surface; e.g., tank wall.
Important that probe does not touch wall.

<6"

<1" (25 mm) diameter pipe and beams, ladder rungs

<12"

<1" (75 mm) diameter pipe and beams, concrete walls

<18"

All remaining objects

SINGLE ROD PROBE CLEARANCE GUIDELINES TABLE

NOTE: Transition Zone is dielectric dependent;

ε

r = dielectric permittivity. The transmitter still operates but

level reading may become nonlinear in Transition Zone.

Model

Coaxial

(7xA, 7xR, 7xT)

Rigid Twin Rod

(7xB)

Flexible Twin Rod

(7x5, 7x7)

HTHP Coaxial

(7xD)

HP Coaxial

(7xP)

Steam

(7xS)

Materials

316/316L SS (Hastelloy C and Monel opt.)

TFE spacers, Viton

®

O-rings

316/316L SS

FEP Coating

Viton

®

O-rings

316/316L SS,

Inconel

®

X750,

Borosilicate seal,

TFE or Peek

spacers

316/316L SS,

Inconel

®

X750,

Borosilicate seal,

TFE spacers

316/316L SS,

Peek

,

Aegis PF 128 O-ring

Diameter

.3125" (8mm) dia. rod
.875" (10mm) dia. tube

Two .5" (13 mm) dia.

Rods, .375"

clearance

between rods

Two .25" (6 mm) dia.

cables; .875"

(22 mm) C

L

to C

L

.3125" (8 mm) diameter rod

.875" (10 mm) diameter tube

.6" (15mm) dia. rod

1.75" (44mm) dia. tube

.6" (15 mm) diameter rod

1.75" (44 mm) diameter tube

Process

Connection

3

4

" NPT, 1" BSP

ANSI or DIN flanges

2" NPT

ANSI or DIN flanges

3

4

" NPT, 1" BSP

ANSI or DIN flanges

3

4

" NPT, 1" BSP

ANSI or DIN flanges

Transition Zone

(Top)

7xA:

1" (25mm)@

ε

r= 1.4

6"(150mm)@

ε

r= 80.0

7xR:

None

1" (25 mm)

+4" inactive

ε

r>20

1" (25 mm)

1" (25 mm)@

ε

r = 2.0

6"(150 mm) @

ε

r = 80.0

8" (200 mm) @

ε

r = 80

Transition Zone

(Bottom)

6" (150 mm) @

ε

r = 1.4

1" (25 mm) @

ε

r = 80.0

12" (305 mm)

6" (150 mm) @

ε

r = 1.4

1" (25 mm) @

ε

r = 80.0

1" (25 mm)@

ε

r = 80

Pull

Force/Tension

N/A

7x5: 3000 lbs.

7x7: 100 lbs.

N/A

Model

7xF, 7xJ Rigid

7x1 Flexible

7x2 Flexible

Materials

316/316L SS (Hastelloy

®

C and Monel optional)

Viton

®

/PEEK

O-rings

316/316L SS, Viton

®

O-rings

Diameter

0.5" (13 mm)

0.1875" (5 mm)

.25" (6 mm)

Blocking Distance - Top

0–36" (0–91 cm)–Probe length dependent (adjustable)

Process

Connection

2" NPT

ANSI or DIN flange

Transition Zone

(Top)

Application Dependent

12" (305 mm) minimum

Transition Zone

(Bottom)

1" @

ε

r >10

12" (305 mm) minimum

Pull Force/Tension

N/A

20 lbs.

3000 lbs.

Side Load

Not more than 3" deflection at

end of 120" (305 cm) probe

Cable not to exceed 5° from vertical

3.6.5 Probe Specifications

Advertising