Table B-1. Troubleshooting Chart

Symptom

Action

Cannot connect using Telnet,

Web browser, or SNMP

software

• Be sure you have configured the agent with a valid IP address, subnet

mask and default gateway.

• If you are trying to connect to the agent via the IP address for a tagged

VLAN group, your management station must include the appropriate tag
in its transmitted frames.

• Check that you have a valid network connection to the switch and that the

port you are using has not been disabled.

• Check network cabling between the management station and the switch.
• If you cannot connect using Telnet or SSH, you may have exceeded the

maximum number of concurrent Telnet/SSH sessions permitted. Try
connecting again at a later time.

Cannot access the on-board

configuration program via a

serial port connection

• Be sure you have set the terminal emulator program to VT100 compatible,

8 data bits, 1 stop bit, no parity, and the baud rate set to any of the
following (9600, 19200, 38400, 57600, 115200 bps).

• Check that the null-modem serial cable conforms to the pin-out

connections provided in the Installation Guide.

Forgot or lost the password

• Contact your local distributor.