Vector Solo AA90 Applicators - Installation

Ransburg

13

AH-08-04.2

Air Hose

For the Vector Solo AA90 to properly function

safely, the 79727-XX Air Hose assembly with

ground wire is required to be used.

Fluid Hose Recommendation

Ransburg recommends using a 7994-XX Fluid

Hose Assembly. This assembly is made to spe-

cifically fit the fluid fitting size engineered into the

applicator. This hose is available as a standard

configuration or as a replacement from your au-

thorized Ransburg distributor.

†

Any user installed fluid hose used must

be rated for 207 bar (3000 psig) working

pressure minimum.

C A U T I O N

!

Filters

1. Install an air filter assembly on the outlet of the

main air regulator. The filter should be 5 micron

with a maximum working pressure of at least

100 psig (6.9 bar). Screw the fitting into the filter

inlet. The filter MUST be installed with the arrow

pointing in the direction of flow. (Refer to the ap-

propriate Filter Assembly manual for Installation

Instruc-tions.)

2. Ransburg recommends that a fluid filter be

installed at the output of the fluid supply (pump,

circulating system, etc.). It is the end user's re-

sponsibility to install the proper filter that meets

their system's requirements.

79698 SOLO

SOLVENTBORNE

INSTALLATION

†

The user

MUST read and be familiar with

the "Safety" section of this manual.

†

This hand held device is intended to be

used by trained personnel ONLY.

†

This manual

MUST be read and thor-

oughly understood by

ALL personnel who

operate, clean, or maintain this equipment!

Special care should be taken to ensure that

the warnings and requirements for operating

and servicing safely are followed. The user

should be aware of and adhere to

ALL local

building and fire codes and ordinances as

well as NFPA, OSHA, and all related coun-

try safety codes prior to installing, operating,

and/or servicing this equipment.

†

Personnel

MUST be GROUNDED to pre-

vent a shock or spark during electrostatic op-

eration.

†

Install and route the hoses so they are

NOT exposed to temperatures in excess of

49°C (120° F) and so that all hose bends are

NO LESS than a (6-inch) (15cm) radius. Fail-

ure to comply with these parameters could

cause equipment malfunction that might cre-

ate

HAZARDOUS CONDITIONS!

W A R N I N G

!

†

For proper safe function of the applicator,

the 79727-XX Air Hose must be used either

standard or quick disconnect style.

W A R N I N G

!

INSTALLATION