Vector Solo AA90 Applicators - Installation

Ransburg

14

AH-08-04.2

INSTALLATION

1. Ensure there is a true earth ground connection

available.

†

Both the fluid source and the air hose

ground must be connected to true earth ground.

W A R N I N G

!

2. Connect the fluid source to true earth ground.

3. Ensure electrostatic On/Off lever is in the Off

position.

4. Connect the air hose ground wire to true earth

ground.

Figure 3: Voltage Off Lever Position

(Bottom View)

5. Connect the air hose or qd stem to the applica-

tor,

thread is left hand pitch, counter-clockwise

to tighten.

Figure 4: Air Hose Connection

Figure 5: Fluid Hose Connection

Interlocks Required

Interlock the solvent supply with the main supply

air to the applicator. When solvent is On, main

supply air to the applicator is Off. Interlocks are

user supplied.

†

The solvent supply must be interlocked

with applicator supply air. Supply air must be

off to the applicator when solvent supply is on.

W A R N I N G

!

†

It is the end users responsibility to insure

the ground end of the 79727-XX air hose is

connected to true earth ground.

W A R N I N G

!

6. Connect fluid hose from grounded fluid source

using a mwrench on the flats, tighten fluid hose.

7. Trigger the applicator with fluid off. Look for

air leaks in any connections.

8. Activate fluid, check for leaks with solvent. Flush

if required. (See "Operation" section for sequence.)

C C W

C C W