Vector Solo AA90 Applicators - Maintenance

Ransburg

39

AH-08-04.2

7. Connect the 79727 Air Hose to main air.

8. Turn on main air and set the pressure so the

pressure gauge [2] in the 79870 Test and Main-

tenance Kit reads 25 psi (1.7 bar). The voltage

kV setpoint lever should be in the high voltage

position (down). The digital multi-meter should

read approximately 15 VDC.

9. If the voltage is outside this range, there is a

problem with the power module circuitry. If the

voltage range is acceptable the power module is

operating correctly, and there is an issue with either

the cascade or the wire connections leading to it.

Figure 72: Set Pressure Gauge to

1.7 BAR (25 psig)

3. Connect the left-hand fitting of the 79727 Air

Hose to the male inlet of the Test and Maintenance

Kit.

4. Insert the tubing [6] into the smaller diameter

hole in the top of the air fitting in the power module.

5. Connect a wire from test point 2 (on the PC

board in the power module) to a true earth ground.

6. Connect a digital multi-meter to test points 1

and 2.

TP-1-Test Point #1

TP-2-Test Point #2

Ground-True Earth

Figure 71: Connect the PC Board to a Digital

Multi-Meter and True Earth Ground

TP-1

TP-2

TP-1

TP-2

1.7 BAR

(25 PSIG)

Air Hose -Ground Wire End

1. Cut the end of the air hose so that end is square.

2. Slide the sleeve and compression ring onto the

air hose end.

3. Push the stem of the fitting all the way into the

into the air hose.

Figure 73: Sleeve and Compression Ring

Figure 74: Ground Fitting Insertion