TROUBLESHOOTING GUIDE (Cont.)

General Problem

Possible Cause

Solution

ELECTRICAL

Paint Leaks

Through Center

of Nozzle

(Failure to Shut Off)

Loose nozzle cap

Improper trigger adjustment

Defective or dirty valve seat

Tighten nut.

Readjust.

Flush out or replace as needed.

Paint Leaks

Around the

Nozzle Cap

Loose nozzle cap

Fluid seal worn

Tighten nut.

Replace seal.

Paint Leaks At

Rear of Barrel

Loose packing nut

Tighten packing nut.

Orange Peel or

Rough Finish

Evaporation rate too fast

Poor atomization

Viscosity too high

Use slower evaporating solvent.

See “Poor Atomization and Distribution”.

Add solvent or heat.

Paint Runs or

Has Poor Hiding

Qualities

Low solids paint

Low viscosity

Excessive delivery

Use less solvent.

Use less solvent.

Use smaller nozzle, wider fan angle,

and lower pump pressure.