Ransburg, Troubleshooting guide (cont.), Vector solo aa90 applicators - maintenance – Ransburg Vector Solo AA90 79698 User Manual
Page 47
![background image](/manuals/348079/47/background.png)
Vector Solo AA90 Applicators - Maintenance
Ransburg
43
AH-08-04.2
TROUBLESHOOTING GUIDE (Cont.)
General Problem
Possible Cause
Solution
ELECTRICAL
Paint Leaks
Through Center
of Nozzle
(Failure to Shut Off)
Loose nozzle cap
Improper trigger adjustment
Defective or dirty valve seat
Tighten nut.
Readjust.
Flush out or replace as needed.
Paint Leaks
Around the
Nozzle Cap
Loose nozzle cap
Fluid seal worn
Tighten nut.
Replace seal.
Paint Leaks At
Rear of Barrel
Loose packing nut
Tighten packing nut.
Orange Peel or
Rough Finish
Evaporation rate too fast
Poor atomization
Viscosity too high
Use slower evaporating solvent.
See “Poor Atomization and Distribution”.
Add solvent or heat.
Paint Runs or
Has Poor Hiding
Qualities
Low solids paint
Low viscosity
Excessive delivery
Use less solvent.
Use less solvent.
Use smaller nozzle, wider fan angle,
and lower pump pressure.