Applicator repair, Ransburg – Ransburg Vector Solo AA90 79698 User Manual

Page 27

Advertising
background image

Vector Solo AA90 Applicators - Maintenance

Ransburg

23

AH-08-04.2

†

DO NOT allow the fluid lines to stand

empty without flushing first! This will cause

dried paint flaking and clogging of the fluid

lines, applicator passages, and/or nozzles.

All repairs should be made on a clean, flat sur-

face. If a vise is used to hold parts during service

or repair, DO NOT clamp onto plastic parts and

always pad the vise jaws!

The following parts should be thoroughly packed

with dielectric grease (LSCH0009-00) leaving

NO

air space or voids when assembling:

• All O-Rings (Teflon o-rings do not need

lubrication)
• Needle Shaft Assembly
• Packing Tube
• Cascade and Barrel

Equipment Required

• Special Multi-Purpose Wrench (79854-00) *
• 4mm, 3mm, and 2.5mm Allen Wrenches *
• Screwdriver (blade)
• Jam Nut Removal Tool (79793-00) *
• Dielectric Grease (LSCH0009-00) *
• Sealant, Medium Strength (7969-10)
• Dowel, 6mm (1/4") diameter
• Air Cap Removal Tool (79642-00) *
• 2.5mm Wrenches (two) (74133-00) *
• Nozzle Wrench (76428-00) *

Note: *Supplied with applicator

APPLICATOR REPAIR

Figure 17: kV Probe

†

There is a 10 giga ohm resistor in the

probe that lowers the output voltage. The

maximum kV rating is at no load. Paint

overspray and other contaminates on the

barrel will lower the kV probe reading.

NOTE

4. Using the meter set to kV, measure the output

voltage of the applicator. Voltage output reading

is between 67 and 75kV.

5. See "Troubleshooting" in the "Maintenance"

section for possible cause of poor performance.

C A U T I O N

!

1 - Full Voltage Setting

2 - 76667-00 kV Probe

3 - 76634-00 Meter

Advertising