Vector Solo AA90 Applicators - Operation

Ransburg

16

AH-08-04.2

Figure 9: Air Pressure at Regulator

4. Increase air pressure to the applicator depend-

ing upon amount of air required to eliminate the

tails. Minimum pressure is 2.75 bar (40 psig) at the

handle. Use either gauge from Maintenance and

Test Kit or use Table I to use a gauge reading at

the wall regulator adjusted for the pressure drop

in the air hose.

Figure 8: Fluid Supply Pressure Adjustment

Figure 10: Fan Pattern Size Adjustment

5. Adjust fan pattern size. Counter-clockwise

decreases fan, clockwise increases fan pressure.

Full closed fan produces the lasgest pattern. Full

open fan produces the smallest fan pattern size.

79727

Hose Length

30m
20m
15m
10m

TABLE I - PRESSURE AT

REGULATOR

Pressure At

Wall Regulator Gauge

3.8 bar (55 psig)
3.5 bar (50 psig)
3.3 bar (48 psig)
3.1 bar (45 psig)

1 - Fluid Supply

2 - Flow Regulator