Vector Solo AA90 Applicators - Operation
Ransburg
16
AH-08-04.2
Figure 9: Air Pressure at Regulator
4. Increase air pressure to the applicator depend-
ing upon amount of air required to eliminate the
tails. Minimum pressure is 2.75 bar (40 psig) at the
handle. Use either gauge from Maintenance and
Test Kit or use Table I to use a gauge reading at
the wall regulator adjusted for the pressure drop
in the air hose.
Figure 8: Fluid Supply Pressure Adjustment
Figure 10: Fan Pattern Size Adjustment
5. Adjust fan pattern size. Counter-clockwise
decreases fan, clockwise increases fan pressure.
Full closed fan produces the lasgest pattern. Full
open fan produces the smallest fan pattern size.
79727
Hose Length
30m
20m
15m
10m
TABLE I - PRESSURE AT
REGULATOR
Pressure At
Wall Regulator Gauge
3.8 bar (55 psig)
3.5 bar (50 psig)
3.3 bar (48 psig)
3.1 bar (45 psig)
1 - Fluid Supply
2 - Flow Regulator