Vector Solo AA90 Applicators - Maintenance

Ransburg

31

AH-08-04.2

Figure 41: Needle Shaft Packing Replacement

5. Clean cavity with non-metallic brush and

non-polar solvent.

6. Replace needle components as required. (See

"Needle Shaft Parts List" in the "Parts Identification"

section for breakdown.)

Needle Shaft Packing

Replacement

1. Pull all rear seal parts off shaft. Replace

components as required.

2. Using two (2)74133 tools, remove carbide ball

and jam nut. Remove packing components.

Figure 42: Needle Shaft Packing Replacement

Figure 39: Needle Shaft Removal

3. Remove rear nut using the 79854-00 Special

Wrench.

NEEDLE SHAFT

REMOVAL/REPLACMENT

1. Remove barrel from the handle using previous

steps.

2. Remove cascade.

Figure 38: Cascade Removal

Figure 40: Needle Shaft Removal

4. Attach a jam nut to the assembly and pull straight

out of the barrel.