Ransburg, Troubleshooting guide (cont.), Vector solo aa90 applicators - maintenance – Ransburg Vector Solo AA90 79698 User Manual

Page 46

Advertising
background image

Vector Solo AA90 Applicators - Maintenance

Ransburg

42

AH-08-04.2

(Continued On Next Page)

TROUBLESHOOTING GUIDE (Cont.)

General Problem

Possible Cause

Solution

ELECTRICAL

Poor Wraparound

Paint Wraps Back

On Operator

No Paint Delivery

Excessive Surging

Persistent Nozzle

Clogging

Poor atomization

Excessive exhaust velocity

Excessive fluid pressure

Applicator held too close to target

Paint too conductive

Poor target ground

See “Poor Atomization and Distribution”.

Reduce (with code limits).

Reduce air pressure to pump.

Hold applicator further back.

Consult Ransburg technical assistance.

Check ground integrity from target

through support to ground.

Poor ground on parts

Applicator held too far from parts

Booth exhaust insufficient or im-

properly rounted

Improper spray technique

Check that parts are fully grounded,

strip workholders.

Hold applicator closer.

Increase, or adjust direction, change

booth filter.

Keep applicator directed at work.

Clogged nozzle

Clogged hose or filters

No pressure at paint pump

Blow out nozzle.

Clean.

If pump air supply OK, consult pump

manual.

Restriction in pump air line

Insufficient pump capacity

Clogged paint filter

Low air volume capacity

Nozzle too large

Remove restriction.

Secure larger pump or reduce output.

Service or replace.

Check factory air capacity.

Replace with correct nozzle.

Paint allowed to dry in nozzle or line

Paint applicator filter too coarse or

damaged

Paint pigments too coarse

Flush lines with solvent after each use.

Replace or change to finer screen

paint filter.

Pre-filter paint and/or use larger

nozzle orifice.

Advertising