Test and maintenance kit usage (79870-00), Ransburg, Vector solo aa90 applicators - maintenance – Ransburg Vector Solo AA90 79698 User Manual

Page 41

Advertising
background image

Vector Solo AA90 Applicators - Maintenance

Ransburg

37

AH-08-04.2

TEST AND MAINTENANCE

KIT USAGE (79870-00)

Figure 66: 79870 Test and Maintenance Kit

1

2

3

4

5

6

79870 TEST AND

MAINTENANCE KIT

Item#

Brass Tee Fitting

100 psi Pressure Gauge

6" Air Hose Assembly

Left Hand Male Fitting

Barb Fitting

Tubing

Description

The 79870 Test and Maintenance Kit allows the

user to determine the inlet pressure at the base

(handle) of the Vector Solo hand-held applicators.

The Test and Maintenance Kit also allows the user

to test the 79835 Power Module Assembly on the

Vector Solo applicator.

The procedure to test the inlet pressure at the

base (handle) of the Vector Solo applicator is as

follows (see Figures 66 and 67):

1. Connect the left-hand fitting of the 79727 Air

Hose to the male inlet of the Test and Maintenance

Kit.

2. Connect the 6" air hose assembly between the

brass tee fitting and the gun air inlet.

3. Install the 1/4 module into the 3/4 module and

tighten the two (2) screws.

Figure 64: Module Assembly

4. Install power module to handle and tighten

three (3) screws. Reinstall the fluid line.

Figure 63: Fluid Fitting Replacement

Figure 65: Power Module Assembly

2. Install the fluid fitting.

C W

3

6

5

2

4

1

Advertising