Routine schedule, Ransburg – Ransburg Vector Solo AA90 79698 User Manual

Page 26

Advertising
background image

Vector Solo AA90 Applicators - Maintenance

Ransburg

22

AH-08-04.2

ROUTINE SCHEDULE

Follow these maintenance steps to extend the

life of the applicator and ensure efficient opera-

tion:

Several Times Daily

• Inspect the air cap for paint accumulation.

Clean as frequently as necessary with a soft

bristled brush and a suitable solvent.

• Clean all insulating surfaces in the system.

Remove paint accumulation from the exterior

of the applicator with a solvent dampened

cloth.

Daily (or at start of each shift)

• Verify that ALL solvent safety containers are

grounded!

• Check within 6m (20-ft.) of the point of opera-

tion (of the applicator) and remove or ground

ALL loose or ungrounded objects.

• Inspect work holders for accumulated coat-

ing materials (and remove such accumula-

tions).

• Check that atomizer assembly is clean and

undamaged.

†

NEVER soak or submerge the electrical

components of the applicator, i.e., barrel,

power module, or handle. Damage and fail-

ure may occur.

†

NEVER remove the fluid nozzle assem-

bly while paint is in the applicator or paint

may enter into the air passages. Clogged or

restricted air passages will cause poor atom-

ization and/or electrical shorting. Air passag-

es that are clogged with conductive material

can lead to excessive current output levels

and consequent low operating voltage or

long-term electrical damage. Before under-

taking any atomizer maintenance procedure.

The applicator barrel

MUST be tilted front down

to remove the fluid nozzle. Failure to do so may

allow paint to enter the air passages, thereby

reducing airflow and damaging the applicator

barrel/cascade. Applicators may be flushed

in lieu of tilting. However, they must be either

flushed or tilted down during nozzle removal!

• Straighten the applicator electrode if necessary.

• Clean the fluid filter, if used.

Electrical Output Test

1. Turn the paint and/or solvent supply OFF.

†

Standard electrode is "snap back"

spray wire electrode.

NOTE

†

Paint and/or solvent supply must be turned

off during this test-risk of fire or explosion.

2. Flush the applicator (see "Flushing Procedure"

in the "Operation" section).

3. Follow instructions for use of the 76634-00 meter.

C A U T I O N

!

C A U T I O N

!

W A R N I N G

!