Vector Solo AA90 Applicators - Maintenance

Ransburg

38

AH-08-04.2

3. Connect the other end of the air hose to the

regulated air supply.

4. Turn on main air. Trigger the applicator with kV

switch on high (down position). Read the pressure

at the 100 psi pressure gauge. This pressure

should be at least 40 psi with air flowing for proper

functioning of the Vector Solo AA90 applicator.

Figure 67: Testing the Pressure

at the Base (Handle)

of the Applicator

The procedure to test the 79835 Power Module

Assembly is as follows:

1. Remove the 79835 Power Module Assembly

from the handle.

Figure 68: Remove Power Module from Handle

2. Connect the barb fitting [5] to the brass tee

fitting [1]. Place the tubing [6] on the end of the

barb fitting.

Figure 69: Connect Barb and Tubing to

Tee Fitting

3. Connect the left-hand fitting of the 79727 Air

Hose to the male inlet of the Test and Maintenance

Kit.

4. Insert the tubing [6] into the smaller diameter

hole in the top of the air fitting in the power module.

Figure 70: Connect Tubing to the Air Fitting

6

1

L H

5

6