Installation, Ransburg, Air filter installation – Ransburg RMA Indirect A11600 User Manual

Page 27

Advertising
background image

INSTALLATION

AIR FILTER INSTALLATION

The following air filter installation guidelines are

essential for optimum performance:

1. 25mm OD (1-inch OD) minimum inbound

main air line.

2. Use only recommended pre-filters and bear-

ing air filters as shown in "Air Filtration Require-

ments" chart in this section. Additional system

air filtration (i.e., refrigerated air dryer) may also

be used if desired.

> With the exception of fluid, dump, and

bearing air, all other pilot and air supply

lines should be bulkheaded and their

diameters increased one size. For ex-

ample: Turbine air should be increased

to a 12mm OD from bulkhead plate to the

volume booster.

NOTE

> Each applicator must have its own filter

for bearing air.

Recommended: RPM-418 or equivalent.

NOTE

3. Mount the bearing air filter as close as pos-

sible to the RMA-303. (DO NOT mount further

than 30-feet (9.1 meters) away.)

4.

DO NOT use tape, pipe dope, or other thread

sealant downstream of the bearing air filter. Loose

flakes of tape or other sealant can break loose

and plug the very fine air holes in the turbine air

bearings.

5. Air heaters are highly recommended for use in

the system

to minimize the effect of excessively

humid conditions. If the heated air will exceed

120

o

F (48.9°C), the heater must be located after

all filters to prevent damage to the filter media.

Bearing Air Supply 6 x 4mm OD

90psi

+

/- 10

(BRG) (Yellow) (621

+

/- 69 kPa)

Bearing Air Return 4mm (5/32") OD 80psi

+

/- 20

(BRG RTN)

(Yellow)

(at atomizer card)

(552

+

/- 138 kPa)

Turbine Air (T.A)

10 X 8mm

Variable

(Green)

Pattern Control

8 X 6mm

Variable

Air 2 (SAO)

(Gray)

Pattern Control

8 X 6mm

Variable

Air 1 (SAI)

(Blue)

Brake Air (BRK) 6 X 4mm

60-100 psi

(if used)

(Orange)

(414 - 689 kPa)

Paint Valve

4mm (5/32") OD 80 psi

+

/- 10

Control (PT)

(Natural)

(552

+

/- 70 kPa)

Dump Valve

4mm (5/32") OD 80 psi

+

/- 10

Control (PD)

(Silver)

(352

+

/- 70 kPa)

Cup Wash Solvent 4mm (5/32") OD 80 psi

+

/- 10 psi

Valve Control (ST) (Blue)

(352

+

/- 70 kPa)

Cup Wash Air

4mm (5/32") OD 80 psi

+

/- 10

(ATI)

(Orange) (352

+

/- 70 kPa)

Valve Control

Cup Wash Air

6 X 4mm

80 - 100 psi

(CWA)

(Green)

(551-689 kPa)

Tube

Air Pressure

Size

Requirements

TUBE SIZE / AIR PRESSURE

REQUIREMENTS

RMA-303 Indirect Charge - Installation

Ransburg

23

LN-9252-06.4