Ransburg, Troubleshooting guide, Rma-303 indirect charge - maintenance – Ransburg RMA Indirect A11600 User Manual

Page 73

Advertising
background image

TROUBLESHOOTING GUIDE

(Continued On Next Page)

General Problem

Possible Causes

Corrective Action

Bad Spray Pattern

Low or No High

Voltage

Low Transfer

Efficiency (or

light coverage)

1. Bell cup damaged

2. Low voltage

3. Paint lodged in shaping air

ring

1. High current draw

2. MicroPak controller cas-

cade

3. Improperly mounted air

turbine

4. Faulty low voltage connec-

tions (usually indicated by

MicroPak feedback fault

light)

5. Faulty high voltage con-

nection

6. MicroPak or cascade fail-

ure

7. MicroPak settings not cor-

rect

8. Damaged high voltage

cable

9. Dielectric breakdown of

high voltage parts

10. Improper color change

(i.e., paint or solvent in

dump line)

1. Low or no high voltage

2. Poor grounding of parts

being coated

1. Replace bell cup.

2. See "Low or No High Voltage" below.

3. Disassemble and clean (see "Maintenance"

section).

1. Check resistance of electrodes.

2. Inspect low voltage at the MicroPak and the

cascade.

a. Faulty low voltage cable.

3. Verify ground connection of air turbine to

earth ground at less than 1 MΩ.

4. a. Make sure quick disconnection electrical

connection is aligned and clean.

b. Check low voltage connection at cascade.

5. Verify that high voltage cable is fully seated in

the cascade and the high voltage ring.

6. Refer to current MicroPak manual for detailed

Troubleshooting Guide.

7. Refer to current "MicroPak" manual for de-

tailed "Troubleshooting Guide."

8. Remove and inspect/measure resistance.

9. Check cascade, high voltage ring, and high

voltage cable. Replace defective parts.

10. Optimize color change.

1. Verify high voltage at electrodes. Normally,

a high voltage setting of 30-70 kV is appropri-

ate for most applications.

2. Verify that parts being coated are properly

grounded (the electrical resistance between

the part and ground must not exceed

1 megohm).

RMA-303 Indirect Charge - Maintenance

Ransburg

69

LN-9252-06.4

Advertising