GENERAL OPERATING

SEQUENCE

Normally, for painting application, the process

sequence should always be:

• Bearing air on (Always on)

• Turbine air on

• Turbine speed to application speed

• Shaping air on

• Start fluid flow off part

• Voltage on

After spraying the object, the sequence should be:

• Voltage lowered to 40-50 kV

• Fluid off

• Shaping air to setback volume

• Turbine speed to set back speed

(30,000 rpm recommended)

> It is recommended to leave bearing air

on, unless the applicator is being serviced

or removed for service.

C A U T I O N

!

Recommended sample cup flush sequence is as

follows:

1. Turbine speed set to 25-30,000 rpm.

2. Shaping air set to 350-450 slpm (12.4-15.9

SCFM).

3. Point atomizer at a grounded object such as a

booth grate. Leave voltage on at 40-50 kV.

4. Assure that solvent solution is heated to 120°F

(49°C) at the applicator.

5. Maintain solvent pressure of 100-150 psi (689-

1,034 kPa). Maintain air push pressure at 80-100

psi (552-689 kPa).

6. Use an alternating sequence of solvent/air to

create a chopping effect. Always insure that the

last step in the sequence is an air push.

A typical sequence is .2 seconds solvent, 1.0

second air push, 1.7 seconds solvent, and 2.0

seconds final air push. This sequence may be

modified for other paints and applications.

If the atomizer is utilizing an applicator cleaning

box, voltage must be turned off.

7. It is recommended that an in-line fluid filter be

installed to ensure that no foreign debris enters the

fluid tip or the external wash nozzle. The fluid filter

must be able to withstand at least 160°F (71°C).

The RMA-303 is versatile in processing the finish of

a component. It can be setup as shown in Figures

9 and 10 to process the typical finish of a target.

Recommended sample cup purge sequence is

as follows (internal cup cleaning):

1. Turbine speed set to 25,000-30,000 rpm.

2. Increase shaping air to 350-450 slpm (12.4-

15.9 SCFM).

3. Paint atomizer at booth grate or insert into bell

cleaning station. Reduce high voltage to 40-50 kV.

TARGET DISTANCE

The distance between the RMA-303 atomizer

and the target will affect the finish quality and

efficiency. Closer distances give a smaller pat-

tern, wetter finish, and greater efficiency. Greater

distance will provide a large pattern size and drier

finish. The MicroPak control circuit will enable

the applicator bell to be operated to within a few

inches of the target without adjusting the voltage

setting. The recommended target distance is 6

to 12-inches (152.4-304.8mm). In general, allow

1-inch (25.4mm) target distance for every 10 kV.