Ransburg, Chart a probe resistance check, Rma-303 indirect charge - maintenance – Ransburg RMA Indirect A11600 User Manual
Page 55

Figure 18: High Voltage Cable Installation
A11343-03
A11343-02
133-147 megohms
209-231 megohms
Chart A
Probe Resistance Check
8 Probe *
8 Probe
Above 5000 ft.
W/In-Line Resistor
Sea Level
Ring
Type
Used At
(location)
Resistance
Reading
Part
#
>
When this electrode assembly is used,
you must use the 78442-00 In-Line Resis-
tor Assembly for the 74793-XX RansPak
cascade and the 78809-00 ground resistor
assembly. The ground resistor assembly
is placed between the atomizer ground
connection and a true earth ground source.
NOTE
* See Note below.
1 3/8"-1 1/4"
(34-31 MM)
FRONT FERRULE
REAR FERRULE
NUT
78441-00
FERRULE ORIENTATION
Figure 17: Shroud Removal
Figure 14: 78842-00 In-Line
Resistor Assembly
Figure 16: 78441-00 Ferrule Orientation
Figure 15: 78809-00 Ground
Resistor Assembly
RMA-303 Indirect Charge - Maintenance
Ransburg
51
LN-9252-06.4