Ransburg – Ransburg RMA Indirect A11600 User Manual

Page 76

Advertising
background image

General Problem

Possible Causes

Corrective Action

Turbine Cannot At-

tain Desired Speed

Loss of Exterior/

Interior Cup Wash

or Lack of Flow

1. Excessive vibration

2. Low or no bearing air

3. Loss of fiber optic/no feed

back

1. Bent of kinked supply

tube

2. No fluid flow

3. Blocked fluid tip or exter-

nal nozzle.

4. Ferrules holding tubing

over-tightened.

1. a. Check bell cup for damage

b. Check bell cup for excessive paint buildup

c. Bell cup loose - tighten to proper torque

d. Check cup and shaft tapers for cleanliness

e. Have manufacturing check bell cup bal-

ance

2. a. Check bearing air pressure (minimum 80

psi) (352 kPa)

b. Check filters for contamination

c. Check for bent or damaged bearing air line

d. Poor turbine air pressure - plant air

e. Damaged speed control cards

3. Damaged fiber optic sensor, bad cable, too

many splices. Maximum three (3) slices per-

mitted.

1. Replace.

2. Check microvalve, check fluid supply source.

3. Clean parts, remove obstruction.

4. Replace tubing and ferrule assembly.

Troubleshooting Guide (Cont.)

RMA-303 Indirect Charge - Maintenance

Ransburg

72

LN-9252-06.4

Advertising