Procedure

Mid

Shift

End of

Shift

Weekly

2 Weeks

RMA-303 PREVENTIVE MAINTENANCE SCHEDULE

Mid Shift Cleaning

X

• Wipe electrodes

• Wipe shroud

• Visually inspect cup

End of Shift Cleaning

X

• Wipe electrodes

• Wipe shroud

• Wipe bell cup down

• Change cloth cover

Shaping Air Shroud

X

X

X

• Clean inner shape air ring

• Clean outer shape air ring

• Remove and clean

Bell cup removal/inspection/

X

X

cleaning/tightening

Fluid tip inspection/cleaning

X

X

Inspect Valve and Seat

X

Assembly in valve module

for leaking

Replace Valves and Seats

X

in valve module

High Voltage Cable

X

X

Inspections

High Voltage Testing

X

Regreasing of High Voltage

X

Cables

Check resistance of High

X

Voltage Electrodes

Regreasing electrode

X

cavitiesof High Voltage Ring

and High Voltage Input

Inspect all screws

X

• Replace if broken

• Inspect for wear

• Tighten per specifications

Frequency (Maximum)

Monthly 3 Months 6 Months Yearly