Procedure
Mid
Shift
End of
Shift
Weekly
2 Weeks
RMA-303 PREVENTIVE MAINTENANCE SCHEDULE
Mid Shift Cleaning
X
• Wipe electrodes
• Wipe shroud
• Visually inspect cup
End of Shift Cleaning
X
• Wipe electrodes
• Wipe shroud
• Wipe bell cup down
• Change cloth cover
Shaping Air Shroud
X
X
X
• Clean inner shape air ring
• Clean outer shape air ring
• Remove and clean
Bell cup removal/inspection/
X
X
cleaning/tightening
Fluid tip inspection/cleaning
X
X
Inspect Valve and Seat
X
Assembly in valve module
for leaking
Replace Valves and Seats
X
in valve module
High Voltage Cable
X
X
Inspections
High Voltage Testing
X
Regreasing of High Voltage
X
Cables
Check resistance of High
X
Voltage Electrodes
Regreasing electrode
X
cavitiesof High Voltage Ring
and High Voltage Input
Inspect all screws
X
• Replace if broken
• Inspect for wear
• Tighten per specifications
Frequency (Maximum)
Monthly 3 Months 6 Months Yearly
(Continued On Next Page)
RMA-303 Indirect Charge - Maintenance
Ransburg
47
LN-9252-06.4