Ransburg, Air filtration requirements – Ransburg RMA Indirect A11600 User Manual

Page 31

Advertising
background image

Filter

Model No.

HAF-503

RPM-417

RPM-418

HAF-15 Element, One

RPM-32 Elements,

Carton of 4

RPM-33 Elements,

Carton of 8

Pre-filter, removes coarse amounts of oil, moisture & dirt. Used

upstream of RPM-417 pre-filter (used in systems with poor air

quality).

Pre-filter, coalescing type, 136 SCFM, 98.5% efficiency particulate

removal .3 to .6 micron, max. aerosol passed 1.0 micron, max.

solid passed .4 micron (dependent upon scfm requirement per

applicator, one RPM-417 can be used with up to three RMA-303

assemblies).

Bearing air filter, coalescing type, 19 SCFM, 99.995% efficiency

particulate removal .3 to .6 micron, max. aerosol passed .6 micron,

max. solid passed .2 micron (one per applicator).

Description/Specifications

Replacement

Element Part No.

AIR FILTRATION REQUIREMENTS

> Each applicator must have its own filter

for bearing air.

Recommended: RPM-418 or equivalent

NOTE

> Air must be properly filtered to ensure

extended turbine life and to prevent contam-

ination of the paint finish. Air which is not

adequately filtered will foul the turbine air

bearings and cause premature turbine failure.

The correct type of filters must be used in

an RMA-303 system. The filter elements

must be replaced on a regular schedule to

assure clean air.

>

It is the end user’s responsibility to en-

sure clean air at all times. Turbine failure

resulting from contaminated air will not

be covered under warranty.

Figure 5 shows the pre-filter(s) and bearing

air filter which are recommended for use

in RMA-303 systems. If other filters are

incorporated in the system, the filters to be

used must have filtering capacities equal

or better than those shown in "Air Filtration

Requirements" above.

>

The user must ensure the bearing air

supply is not inadvertently turned off

while the RMA-303 air motor is turning.

This will cause air bearing failure.

C A U T I O N

!

RMA-303 Indirect Charge - Installation

Ransburg

27

LN-9252-06.4

Advertising