CHECKING PROBES

Check atomizer voltage using the Ransburg Test

Meter Kit (76652-01 or 76652-04). Verify that the

ouput voltages have not varied much from the

setup standard. A drastic change in voltage can

be an early indicator of a component or system

problem. The data shown was collected under

the ideal lab conditions using a clean atomizer

and an unloaded fluid delivery system.

The following data is for use with the RMA-303. The

output voltage measured at the bell will normally

range between 91% and 97% of the kV set point

displayed at the control unit. Typically setting for

spraying is 70 kV.

High Voltage Ring Inspection

Examine entire ring for burning marks indicated

by metled plastic or blackened areas around or

near where the electrodes are located, the area

where the high voltage input tube is, and on the

inner diameter of the ring.

If any area is found with the above conditions, the

ring must be replaced.

After verifying, clean all old dielectric grease from

the eight (8) protrusions on the front of the ring

and from the concentric circles at the high voltage

input protrusion.

Reapply dielectric grease (LSCH0009) to both of

these areas. The eight (8) protrusions only require

a thin film of grease. The high voltage input area

must be filled with grease allowing no air voids.

Excess grease will be squeezed out when the

input tube and high voltage cable are installed.

Wipe off all excess grease.

Figure 53: High Voltage Ring Lubrication

ELECTRODE

RESISTANCE TEST

To verify that all indirect charge electrodes are

functioning, place one lead of a Yokogama meg-

ohm meter or equivalent to the metal contact at

the base of the electrode and the other end to the

small metal wire at the tip of the electrode. Refer

to the "Electrode Assembly Resistance Reading"

chart in this section for the proper resistance

reading for the electrode assembly.

Figure 54: Electrode Resistance Test

MEGOHM

METER

FILL THIS CAVITY

WITH DIELECTRIC GREASE

DO NOT FILL CENTER CAVITY

WITH DIELECTRIC GREASE