background image

PROTECTIVE COVERS

It is recommended to use covers to reduce the

amount of overspray build-up on the shroud and

electrodes. Two covers are available, a white

lint free stretch cloth for covering the probes and

a foam cover (green) for the front shaping air

shroud. The white cloth cover should cover all of

the electrode except for the last 1-inch (25-4mm).

The green foam cover should be installed until

just past the radius edge of the shroud. Care is

to be taken when installing the white cloth covers

over the electrodes, do not bend them. (Devise a

fixture to help slide the cover over easier.)

When cleaning, do not get covers wet, it will attract

more overspray more quickly. Push them back,

clean surface, dry thoroughly, and slide back to

original position. Depending on conditions, covers

should be replaced after each shift (8 hours).

>

Make sure covers

DO NOT trap mois-

ture. Moisture on covers can inhibit the

performance of the applicator. Large

amounts of trapped fluids can become

floating grounds. These conditions may

lead to unwanted sudden discharge of

energy in the form of a spark.

C A U T I O N

!

Covers:

A11565-00 White Stretch, Lint Free Covers

A11564-00 - Foam Elastic Covers (Green)

RMA-303 Indirect Charge - Operation

Ransburg

38

LN-9252-06.4

Advertising